MR-IMAGING ARTIFACTS THAT SIMULATE DISEASE - HOW TO RECOGNIZE AND ELIMINATE THEM

被引:59
作者
ARENA, L
MOREHOUSE, HT
SAFIR, J
机构
[1] NYU,DEPT RADIOL,NEW YORK,NY 10016
[2] VET ADM MED CTR,DIV MAGNET RESONANCE IMAGING,NEW YORK,NY 10010
[3] ALBERT EINSTEIN COLL MED,DEPT RADIOL,NEW YORK,NY
[4] ALBERT EINSTEIN COLL MED,DEPT PATHOL,NEW YORK,NY
[5] LAKEVILLE RADIOL,GREAT NECK,NY
关键词
MAGNETIC RESONANCE (MR); ARTIFACT; CHEMICAL SHIFT; FLOW ARTIFACT; MOTION CORRECTION; PHYSICS;
D O I
10.1148/radiographics.15.6.8577963
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Occasionally, artifacts may simulate pathologic conditions on magnetic resonance (MR) images, Motion artifacts especially affect images of the chest and abdomen, There are a number of techniques for reducing motion artifacts, including respiratory and cardiac gating, k-space phase reordering, gradient moment nulling, even echo rephasing, and physical restraints, Aliasing occurs when the field of view does not include all of the anatomic structures present in the imaged section, Aliasing artifacts can be eliminated by increasing the field of view, oversampling, and use of saturation pulses or surface coils, Truncation artifacts represent the difference between the original and the reconstructed image and can be reduced with data extrapolation algorithms or image filtering, Chemical shift artifacts and magnetic susceptibility artifacts are due to a local deformity of the magnetic field, resulting in spatial misregistration, Chemical shift artifacts are more severe in images acquired with a narrow-bandwidth technique; magnetic susceptibility artifacts are more severe in images acquired with a long echo time, Pitfalls in the interpretation of MR images can be avoided by becoming familiar with the appearances and causes of common MR imaging artifacts.
引用
收藏
页码:1373 / 1394
页数:22
相关论文
共 33 条
[21]  
SAKURAI K, 1992, AM J NEURORADIOL, V13, P1301
[22]  
SANDERS JA, 1995, FUNCTIONAL BRAIN IMA
[23]  
SCHWARTZ M, 1970, INFORMATION TRANSMIS
[24]  
SHORTLEY G, 1971, ELEMENTS PHYSICS
[25]   APPLICATION OF AUTOREGRESSIVE MOVING AVERAGE PARAMETRIC MODELING IN MAGNETIC-RESONANCE IMAGE-RECONSTRUCTION [J].
SMITH, MR ;
NICHOLS, ST ;
HENKELMAN, RM ;
WOOD, ML .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (03) :132-139
[26]   THORACIC AORTIC DISSECTION - PITFALLS AND ARTIFACTS IN MR IMAGING [J].
SOLOMON, SL ;
BROWN, JJ ;
GLAZER, HS ;
MIROWITZ, SA ;
LEE, JKT .
RADIOLOGY, 1990, 177 (01) :223-228
[27]  
TSURUDA JS, 1991, AM J NEURORADIOL, V12, P237
[28]   TRUNCATION ARTIFACT - A POTENTIAL PITFALL IN MR-IMAGING OF THE MENISCI OF THE KNEE [J].
TURNER, DA ;
RAPOPORT, MI ;
ERWIN, WD ;
MCGOULD, M ;
SILVERS, RI .
RADIOLOGY, 1991, 179 (03) :629-633
[29]  
Viterbi A., 1966, PRINCIPLES COHERENT
[30]   PELVIS IMAGING WITH MR - TECHNIQUE FOR IMPROVEMENT [J].
WINKLER, ML ;
HRICAK, H .
RADIOLOGY, 1986, 158 (03) :848-849