MEASUREMENTS OF VOID GAS-PRESSURE DURING COMBINED THERMAL AND PARTIAL DISCHARGE AGING OF EPOXY

被引:15
作者
GJAERDE, AC
机构
[1] Norwegian Electric Power Research, Inst, Trondheim
关键词
VOID GAS PRESSURE; EPOXY AGING; INSULATION DEGRADATION;
D O I
10.1049/ip-smt:19951631
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The combined effect of partial discharges and temperature on epoxy has been investigated. The void gas pressure exhibited a characteristic development with a short initial fluctuation followed by a linear decrease. The slope of the linear pressure curve was a function of temperature level and voltage stress. During ageing, the initially occurring uniform distribution of large discharges, type I pattern, was replaced by a type II pattern and eventually a type II PD pattern, displaying a few large discharges followed by many small discharges, appeared. The type III pattern possibly indicates that some discharges have changed or are about to change into swarming pulsive microdischarges. No correlation could be found between the appearance of the type III pattern and the development of void gas pressure. In the linear region, the development of void gas pressure was unaffected by any changes in PD activity. Based on this result it is suggested that even if the PD pattern changes, the total contribution to insulation degradation remains the same and hence also the degradation rate as expressed by the continuous development of void gas pressure.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 20 条
[1]   SOME OBSERVATIONS ON CHARACTER OF CORONA DISCHARGES IN SHORT GAP SPACES [J].
BARTNIKAS, R .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1971, EI 6 (02) :63-+
[2]   THE IMPORTANCE OF STATISTICAL CHARACTERISTICS OF PARTIAL DISCHARGE DATA [J].
FRUTH, B ;
NIEMEYER, L .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (01) :60-69
[3]  
GARTON CG, 1962, GAS DISCHARGES ELECT, P412
[4]  
GJAERDE AC, 1994, PHENOMENOLOGICAL INS, P94
[5]  
GJAERDE AC, 1994, THESIS NORWEGIAN I T
[6]   MEASUREMENTS OF PARTIAL DISCHARGES BY COMPUTER AND ANALYSIS OF PARTIAL DISCHARGE DISTRIBUTION BY THE MONTE-CARLO METHOD [J].
HIKITA, M ;
YAMADA, K ;
NAKAMURA, A ;
MIZUTANI, T ;
OOHASI, A ;
IEDA, M .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1990, 25 (03) :453-468
[7]   SPARK-TO-GLOW DISCHARGE TRANSITION DUE TO INCREASED SURFACE CONDUCTIVITY ON EPOXY-RESIN SPECIMENS [J].
HUDON, C ;
BARTNIKAS, R ;
WERTHEIMER, MR .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1993, 28 (01) :1-8
[8]  
HUDON C, 1991, ANAL DEGRADATION PRO, P237
[9]  
HUDON C, 1992, SURFACE GAS PHASE RE, P725
[10]  
ICHIKAWA H, 1993, 8TH INT S HIGH VOLT