THE ATOMIZATION OF CADMIUM IN GRAPHITE FURNACES

被引:5
作者
CHAKRABORTY, R
DAS, AK
CERVERA, ML
DELAGUARDIA, M
机构
[1] UNIV VALENCIA,DEPT QUIM ANALIT,E-46100 BURJASSOT,SPAIN
[2] UNIV BURDWAN GOLAPBAG,DEPT CHEM,BURDWAN 713104,W BENGAL,INDIA
来源
ANALYTICAL PROCEEDINGS | 1995年 / 32卷 / 07期
关键词
D O I
10.1039/ai9953200245
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effect of the atomization temperature on the analysis of cadmium in graphite furnaces has been studied. A comparison of the electrothermal atomic absorption spectrometry (ETAAS) determination of total Cd in animal tissues was carried out with Zeeman effect and deuterium background corrections. A detailed study of the atomic absorption profile and background correction of cadmium, as well as the variation of absorbance values at different atomization temperatures, in both peak-height and integrated modes, has been made, The accuracy of the ETAAS determination of Cd in tissue samples, using various atomization temperatures, has also been evaluated, having found that an atomization temperature equal or higher than 1600 degrees C is necessary in order to obtain accurate and reproducible results, The use of low atomization temperatures, suggested in some published works, makes it possible to obtain accurate results, but the slow production of gaseous atoms of cadmium can affect the precision of the absorbance measurements and strongly affects the peak area values. On the other hand, the use of atomization temperatures higher than 2000 degrees C produces bad recoveries of cadmium in the analysis of certified tissue samples.
引用
收藏
页码:245 / 249
页数:5
相关论文
共 26 条
[1]   LOW-VOLUME MICROWAVE DIGESTION OF MARINE BIOLOGICAL TISSUES FOR THE MEASUREMENT OF TRACE-ELEMENTS [J].
BALDWIN, S ;
DEAKER, M ;
MAHER, W .
ANALYST, 1994, 119 (08) :1701-1704
[2]   DIRECT DETERMINATION OF CADMIUM IN SEA-WATER USING ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY WITH ZEEMAN-EFFECT BACKGROUND CORRECTION AND OXALIC-ACID AS A CHEMICAL MODIFIER [J].
CABON, JY ;
LEBIHAN, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :383-388
[3]  
CHAKRABORTY RN, UNPUB
[4]   ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY WITH STABILIZED AQUEOUS STANDARDS FOR THE DETERMINATION OF CADMIUM IN WHOLE-BLOOD [J].
DEBENZO, ZA ;
FRAILE, R .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :283-288
[5]  
DHAESE PC, 1991, CLIN CHEM, V37, P1583
[6]   USE OF ORGANOPHOSPHORUS VAPORS AS CHEMICAL MODIFIERS FOR THE DETERMINATION OF CADMIUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
EBDON, L ;
FISHER, AS ;
HILL, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (03) :511-513
[7]   GRAPHITE-FURNACE ATOMIZATION BEHAVIOR OF LEAD CONTAINED IN CLINICAL AND ENVIRONMENTAL MATERIALS IN THE PRESENCE OF PALLADIUM-INDUCED ISOFORMATION AND CITRIC-ACID [J].
GRANADILLO, VA ;
NAVARRO, JA ;
ROMERO, RA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) :615-622
[8]   DETERMINATION OF CADMIUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
KOMAREK, J ;
SLANINOVA, M ;
VRESTAL, J ;
SOMMER, L .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1991, 56 (10) :2082-2095
[10]   DIRECT DETERMINATION OF CADMIUM IN NATURAL-WATERS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY WITHOUT MATRIX MODIFICATION [J].
LUM, KR ;
CALLAGHAN, M .
ANALYTICA CHIMICA ACTA, 1986, 187 :157-162