IN-VITRO CHARACTERISTICS OF WHITE CELL-REDUCED SINGLE-UNIT PLATELET CONCENTRATES STORED IN SYRINGES

被引:13
作者
PISCIOTTO, PT
SNYDER, EL
SNYDER, JA
FRATTAROLI, S
HOPFER, SM
RINDER, HM
SMITH, BR
机构
[1] UNIV CONNECTICUT,SCH MED,DEPT LAB MED,FARMINGTON,CT 06032
[2] YALE UNIV,SCH MED,DEPT LAB MED,NEW HAVEN,CT 06510
[3] YALE UNIV,SCH MED,DEPT INTERNAL MED,NEW HAVEN,CT 06510
[4] YALE UNIV,SCH MED,DEPT PEDIAT,NEW HAVEN,CT 06510
关键词
D O I
10.1046/j.1537-2995.1994.34594249052.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Platelet concentrates (PCs) for premature infants may be subjected to filtration, dentrifugation, and various storage conditions before transfusion. Study design and Methods: As there are few data on the cumulative effect of these procedures on PCs, platelet properties (including biochemical and functional in vitro assays) were evaluated after the Processing of single units of PCs through a 1-unit-capacity high-efficiency white cell (WBC) reduction filter followed by syringe storage at either 22 or 37 degrees C for 6 hours. Two- and 5-day-old PCs, volume-reduced PCs, and prestorage WBC-reduced PCs were evaluated. Results: WBC filtration consistently resulted in a 3 to 4 log(10) reduction in WBCs, with less than 15-percent platelet loss. Nd adverse effects of platelet function or evidence of increased platelet activation as determined by the percentage of P-selectin positivity were noted. A decrease in pH associated with increased lactate production and consumption of glucose was observed following syringe storage under all conditions tested. Such changes were most pronounced, however, with volume-reduced PCs stored at 37 degrees C (pH 6.31 +/- 0.15, lactate 23.0 +/- 3.06 mmol/L). All PH levels at the end of storage were above the minimum Food and Drug Administration requirement (pH 6.0). Conclusion: The in vitro data suggest that single units of PCs can undergo WBC filtration followed by syringe storage for up to 6 hours and still maintain acceptable storage characteristics. The practice of maintaining volume-reduced PCs in syringes for 6 hours at 37 degrees C in isolettes during transfusion should, however, be avoided.
引用
收藏
页码:407 / 411
页数:5
相关论文
共 18 条
  • [1] CORRELATED MEASUREMENT OF PLATELET-RELEASE AND AGGREGATION IN WHOLE-BLOOD
    AULT, KA
    RINDER, HM
    MITCHELL, JG
    RINDER, CS
    LAMBREW, CT
    HILLMAN, RS
    [J]. CYTOMETRY, 1989, 10 (04): : 448 - 455
  • [2] BERTOLINI F, 1992, TRANSFUSION, V32, pS5
  • [3] PRODUCTION OF MONOCLONAL-ANTIBODIES SPECIFIC FOR PLATELET ACTIVATION ANTIGENS AND THEIR USE IN EVALUATING PLATELET-FUNCTION
    CARMODY, MW
    AULT, KA
    MITCHELL, JG
    ROTE, NS
    NG, AK
    [J]. HYBRIDOMA, 1990, 9 (06): : 631 - 641
  • [4] PREVENTION OF TRANSFUSION-ACQUIRED CYTOMEGALO-VIRUS INFECTION IN INFANTS BY BLOOD FILTRATION TO REMOVE LEUKOCYTES
    GILBERT, GL
    HUDSON, IL
    HAYES, K
    JAMES, J
    [J]. LANCET, 1989, 1 (8649) : 1228 - 1231
  • [5] HANDIN R I, 1970, Transfusion (Bethesda), V10, P305
  • [6] EVALUATION OF PLATELET CONCENTRATES STORED FOR 5 DAYS WITH REDUCED PLASMA-VOLUME
    HOLME, S
    HEATON, WA
    MOROFF, G
    [J]. TRANSFUSION, 1994, 34 (01) : 39 - 43
  • [7] STUDY OF VARIABLES AFFECTING QUALITY OF PLATELETS STORED AT ROOM-TEMPERATURE
    KUNICKI, TJ
    TUCCELLI, M
    BECKER, GA
    ASTER, RH
    [J]. TRANSFUSION, 1975, 15 (05) : 414 - 421
  • [8] MOROFF G, 1991, Transfusion Medicine Reviews, V5, P48, DOI 10.1016/S0887-7963(91)70192-2
  • [9] REDUCTION OF THE VOLUME OF STORED PLATELET CONCENTRATES FOR USE IN NEONATAL PATIENTS
    MOROFF, G
    FRIEDMAN, A
    ROBKINKLINE, L
    GAUTIER, G
    LUBAN, NLC
    [J]. TRANSFUSION, 1984, 24 (02) : 144 - 146
  • [10] INVITRO CHARACTERISTICS OF VOLUME-REDUCED PLATELET CONCENTRATE STORED IN SYRINGES
    PISCIOTTO, PT
    SNYDER, EL
    NAPYCHANK, PA
    HOPFER, SM
    [J]. TRANSFUSION, 1991, 31 (05) : 404 - 408