GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC DETERMINATION OF 5-HYDROXYMETHYLURACIL IN HUMAN URINE BY STABLE-ISOTOPE DILUTION
被引:19
作者:
FAURE, H
论文数: 0引用数: 0
h-index: 0
机构:
SESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCESESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCE
FAURE, H
[1
]
INCARDONA, MF
论文数: 0引用数: 0
h-index: 0
机构:
SESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCESESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCE
INCARDONA, MF
[1
]
BOUJET, C
论文数: 0引用数: 0
h-index: 0
机构:
SESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCESESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCE
BOUJET, C
[1
]
CADET, J
论文数: 0引用数: 0
h-index: 0
机构:
SESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCESESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCE
CADET, J
[1
]
DUCROS, V
论文数: 0引用数: 0
h-index: 0
机构:
SESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCESESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCE
DUCROS, V
[1
]
FAVIER, A
论文数: 0引用数: 0
h-index: 0
机构:
SESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCESESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCE
FAVIER, A
[1
]
机构:
[1] SESAM,DEPT RECH FONDAMENTALE MAT CONDENSEE,LES ACIDES NUCL LAB,F-38041 GRENOBLE,FRANCE
来源:
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS
|
1993年
/
616卷
/
01期
关键词:
D O I:
10.1016/0378-4347(93)80465-G
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
A method for the determination of 5-hydroxymethyluracil in urine is described. 5-Hydroxymethyluracil was extracted by reversed-phase chromatography and quantified by gas chromatography-mass spectrometry as tert.-butyldimethylsilyl derivative. Since natural 5-hydroxymethyluracil contained ca. 22% of M + 2 species, an internal standard consisting of [1,3-N-15(2),5-H-2(2)]hydroxymethyluracil was used to correct losses during extraction, evaporation and derivatization. Between-run precision of this method was 7.79%. and concentrations as low as 1.87 nM could be measured. This sensitivity and precision could not be obtained with trimethylsilyl derivatives.
机构:
UNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV CELL & MOLEC BIOL, BERKELEY, CA 94720 USAUNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV CELL & MOLEC BIOL, BERKELEY, CA 94720 USA
AMES, BN
GOLD, LS
论文数: 0引用数: 0
h-index: 0
机构:
UNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV CELL & MOLEC BIOL, BERKELEY, CA 94720 USAUNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV CELL & MOLEC BIOL, BERKELEY, CA 94720 USA
机构:
UNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV CELL & MOLEC BIOL, BERKELEY, CA 94720 USAUNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV CELL & MOLEC BIOL, BERKELEY, CA 94720 USA
AMES, BN
GOLD, LS
论文数: 0引用数: 0
h-index: 0
机构:
UNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV CELL & MOLEC BIOL, BERKELEY, CA 94720 USAUNIV CALIF BERKELEY, LAWRENCE BERKELEY LAB, DIV CELL & MOLEC BIOL, BERKELEY, CA 94720 USA