A LIQUID SCINTILLATION BETA-RADIOMETER WITH PROTECTION SCINTILLATOR

被引:0
|
作者
ANTONENKO, GI
SAVINA, VI
机构
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We describe the design of the detection module of a liquid scintillation radiometer with a protection scintillator whose signals are utilized in the radiometer. Using Russian-made materials to construct the detection unit, a ZhS-8 liquid scintillator, and specially selected FEU-118 photomultipliers, together with nonstandard experimental methods, we reduced the background level to 0.08 sec-1 and obtained a registration efficiency of 16% (without a quenching correction); the minimum perceivable activity was 10 Bk per liter of water with an accuracy of 40%.
引用
收藏
页码:443 / 445
页数:3
相关论文
共 50 条
  • [1] A low-noise beta-radiometer
    Antonenko, GI
    Savina, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1995, 38 (03) : 391 - 395
  • [2] AUTOMATIC COMPENSATION OF GAMMA-BACKGROUND IN A BETA-RADIOMETER
    PETUSHKO.AA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (05): : 1084 - &
  • [3] A LIQUID SCINTILLATION TRITIUM RADIOMETER
    LENSKII, LA
    BELOV, GV
    INDUSTRIAL LABORATORY, 1968, 34 (11): : 1706 - &
  • [4] A NEW SCINTILLATOR FOR LIQUID SCINTILLATION COUNTING
    SCALES, B
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1967, 18 (01): : 1 - &
  • [5] Scintillation balloon for liquid scintillator base Neutrinoless double beta decay search experiments
    Obara, S.
    Gando, Y.
    Ishidoshihro, K.
    16TH INTERNATIONAL CONFERENCE ON TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS (TAUP 2019), 2020, 1468
  • [6] Scintillation balloon for neutrinoless double-beta decay search with liquid scintillator detectors
    Obara, S.
    Gando, Y.
    Ishidoshiro, K.
    PROGRESS OF THEORETICAL AND EXPERIMENTAL PHYSICS, 2019, 2019 (07):
  • [7] USE OF AQUASOL SCINTILLATOR MIXTURE FOR LIQUID SCINTILLATION COUNTING OF BETA RADIOACTIVITY IN BIOLOGICAL TISSUE
    WIEBE, LI
    STEVENS, A
    NOUJAIM, AA
    EDISS, C
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (11): : 663 - &
  • [8] NEW EMULSIVE SCINTILLATOR FOR LIQUID SCINTILLATION MEASUREMENTS
    FUJII, H
    TAKIUE, M
    ISHIKAWA, H
    APPLIED RADIATION AND ISOTOPES, 1989, 40 (03) : 235 - 238
  • [9] MINIMIZING OF THE SCINTILLATOR INPUT FOR THE LIQUID SCINTILLATION-COUNTING
    RUSSOW, R
    ISOTOPENPRAXIS, 1988, 24 (11-12): : 465 - 467
  • [10] Monte Carlo modeling of beta-radiometer device used to measure milk contaminated as a result of the Chernobyl accident
    Khrutchinsky, A.
    Kutsen, S.
    Minenko, V.
    Zhukova, O.
    Luckyanov, N.
    Bouville, A.
    Drozdovitch, V.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (06) : 1089 - 1093