Ablative and mechanical properties of quartz phenolic composites

被引:8
作者
Gregori, Maria L. [1 ]
Barros, Edson A. [2 ]
Filho, Gilberto P. [2 ]
Pardini, Luiz Claudio [1 ]
Costa, Sonia F. [1 ]
机构
[1] Inst Aeronaut & Space, Sao Jose Dos Campos, Brazil
[2] Technol Inst Aeronaut, Sao Jose Dos Campos, Brazil
关键词
Ablation; Quartz phenolic; Mechanical properties; Thermal protection systems;
D O I
10.5028/jatm.2009.01016368
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Quartz phenolic composites have been applied to thermal protection systems (TPSs) for reentry vehicles since the late fifties due to their excellent ablative resistance and mechanical performance. TPSs must withstand the aggressive reentry environment, such as atomic oxygen, when submitted to veiy high temperatures (> 10000 degrees C) and heat flux. The ablative performance of composites is influenced by both base materials and environmental parameters during the ablation process. For TPS systems phenolic resin is usually used as the base matrix due to its ability to form a stable char during decomposition. This char plays an important role in the absorption of the heat generated during the ablation process. During re-entry, parts of the charred matrix can he abrasively removed by shear force due to high pressure and velocity. In this work the ablative and mechanical properties of quartz phenolic composites were evaluated in order to identify the range of properties suitable fbr the use of these materials as thermal protection systems for space vehicles. Quartz fabric having an areal weight of 680 g/m(2) and a resole-type phenolic resin were used to prepare the composites. The resin has a viscosity of 165 MPa at 20 degrees C. The prepreg material was cured by heating under pressure of 100 bar in a mold. The resin content of the prepreg obtained was about 50 per cent. The mechanical properties evaluated were, tensile, shear and flexural strength. The results obtained showed that this material has average values of 38.5 MPa, 52 MPa and 85 MPafor tensile, shear andjlexural strength, respectively. The ablative tests were carried out in a high-energy air plasma in ambient atmosphere and the mass losses were measured for different exposure time.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 7 条
[1]  
[Anonymous], C1275 ASTM
[2]  
[Anonymous], D5379 ASTM
[3]  
[Anonymous], D790 ASTM
[4]  
Kanno Y, 1993, P 9 INT C COMP MAT M, VVI, P120
[5]  
Knop A., 1985, PHENOLIC RESIN CHEM
[6]  
Kumara R, 2005, MAT SCI ENG A-STRUCT, V412, P6670
[7]  
[No title captured]