EVALUATION OF MENISCAL TEARS - FAST SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO MAGNETIC-RESONANCE-IMAGING

被引:23
|
作者
ANDERSON, MW
RAGHAVAN, N
SEIDENWURM, DJ
GREENSPAN, A
DRAKE, C
机构
[1] RADIOL ASSOCIATES SACRAMENTO,SACRAMENTO,CA
[2] UNIV CALIF DAVIS,SCH MED,DEPT STAT,SACRAMENTO,CA
关键词
MAGNETIC RESONANCE IMAGING; KNEE; MENISCI; FAST SPIN ECHO;
D O I
10.1016/S1076-6332(05)80166-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We compared the performance of fast spin-echo (FSE) with conventional spin-echo (CSE) magnetic resonance (MR) imaging sequences in the detection of meniscal tears. Methods. Seventy-three patients underwent MR examination of the knee for suspected internal derangement. Each patient was scanned with a CSE sequence and one of two FSE sequences. The primary difference between the two FSE sequences consisted of the echo train length (ETL). Thirty-seven patients (group 1) were scanned with the FSE I sequence (ETL = 8), and 36 patients (group 2) were scanned with the FSE II sequence (ETL = 4). Menisci were graded as torn or not torn on the basis of their MR appearance, The sequences were compared with each other and with the surgical findings in 31 patients who underwent arthroscopy. Results. In group 1, there was a significant discrepancy between the CSE and FSE I techniques (p = .006). The FSE I sequence detected only 11 of 19 surgically proven torn menisci as opposed to 18 of 19 detected with the CSE sequence. The FSE II sequence performed significantly better in group 2, with an accuracy equal to that of the CSE sequence. Conclusion. FSE sequences are extremely technique dependent with regard to detecting meniscal tears and should not replace CSE sequences in this setting until further studies are performed to optimize the technique.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 50 条
  • [21] Artifacts induced by concomitant magnetic field in fast spin-echo imaging
    Zhou, XJ
    Tan, SG
    Bernstein, MA
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (04) : 582 - 591
  • [22] FAST SPIN-ECHO MRI IN OTOLOGY
    PHELPS, PD
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1994, 108 (05) : 383 - 394
  • [23] Accuracy of 3-T MRI using fast spin-echo technique to detect meniscal tears of the knee
    Ramnath, RR
    Magee, T
    Wasudev, N
    Murrah, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) : 221 - 225
  • [24] MR KNEE IMAGING - AXIAL 3DFT GRASS PULSE SEQUENCE VERSUS SPIN-ECHO IMAGING FOR DETECTING MENISCAL TEARS
    AUBEL, S
    HEYD, RL
    THAETE, FL
    WOZNEY, P
    MAGNETIC RESONANCE IMAGING, 1992, 10 (04) : 531 - 539
  • [25] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [26] Magnetic resonance ultrashort echo time spin-echo imaging of the deepest layers of articular cartilage
    Gao Song
    Du Jiang
    Wang Fei
    Bao ShangLian
    SCIENCE CHINA-LIFE SCIENCES, 2013, 56 (07) : 672 - 674
  • [27] Comparison of fat-saturation fast spin echo versus conventional spin-echo MRI in the detection of rotator cuff pathology
    Needell, SD
    Zlatkin, MB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 674 - 677
  • [28] REDUCTION OF MRT TIMING FOR EXAMINATION OF THE FEMALE PELVIS USING T2-WEIGHTED FAST SPIN-ECHO (FSE) TECHNIQUES - QUANTITATIVE AND QUALITATIVE COMPARISON OF CONVENTIONAL SPIN-ECHO (SE) AND FAST SPIN-ECHO (FSE)
    HALDEMANN, RC
    KRESTIN, GP
    DUEWELL, S
    MARINCEK, B
    VONSCHULTHESS, GK
    SAADIELMANDJRA, M
    FUCHS, WA
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (02): : 127 - 132
  • [29] CONTRAST ON T2-WEIGHTED IMAGES OF THE LUMBAR SPINE USING FAST SPIN-ECHO AND GATED CONVENTIONAL SPIN-ECHO SEQUENCES
    CHAPPELL, PM
    GLOVER, GH
    ENZMANN, DR
    NEURORADIOLOGY, 1995, 37 (03) : 183 - 186
  • [30] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Zhang, Jing
    Chen, Lang
    Wang, Qiu-Xia
    Liu, Rong
    Zhu, Wen-Zhen
    Luo, Xin
    Peng, Li
    Xiong, Wei
    NEURORADIOLOGY, 2015, 57 (04) : 357 - 365