CORONARY LUMEN AT 6-MONTH FOLLOW-UP OF A NEW RADIOPAQUE CORDIS TANTALUM STENT USING QUANTITATIVE ANGIOGRAPHY AND INTRACORONARY ULTRASOUND

被引:25
|
作者
OZAKI, Y
KEANE, D
NOBUYOSHI, M
HAMASAKI, N
POPMA, JJ
SERRUYS, PW
机构
[1] ERASMUS UNIV ROTTERDAM, CTR THORAX, CATHETERIZAT LAB, 3000 DR ROTTERDAM, NETHERLANDS
[2] KOKURA MEM HOSP, DEPT CARDIOL, CATHETERIZAT LAB, KITAKYUSHU, FUKUOKA, JAPAN
[3] WASHINGTON HOSP CTR, DEPT INTERNAL MED, DIV CARDIOL, WASHINGTON, DC 20010 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1995年 / 76卷 / 16期
关键词
D O I
10.1016/S0002-9149(99)80322-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the reliability of geometric (edge-detection) quantitative coronary angiographic analysis (QCA) of restenosis within a new Cordis tantalum stent, QCA and intracoronary ultrasound (ICUS) measurements were compared in both an experimental restenosis model and in the clinical follow-up of patients, In the experimental series, Plexiglas(TM) phantom vessels with concentric stenosis channels ranging from 0.75 to 3.0 mm in diameter and with a reference diameter of 3.0 mm were imaged bath before and after their insertion in tantalum stents, In the clinical series, the agreement of QCA and ICUS measurements were studied in 23 patients who had undergone coronary implantation of the new tantalum stent and in 23 patients who had undergone balloon angioplasty 6 months previously, The reliability of QCA declined in the presence of the radiopaque stent (accuracy of QCA decreased from -0.07 to -0.12 mm), whereas the reliability of lumen measurements by ICUS was independent of the presence of the radiopaque stent (-0,12 and -0.13 mm), Without the stent, the average minimal luminal diameter (MLD) obtained by QCA of the 1,00 mm Plexiglas vessel was 1.00 +/- 0.01 mm, and the 3.00 mm reference vessel diameter was 2.81 +/- 0.05 mm, providing a 64 +/- 1% diameter stenosis, After introduction of the stent, the average MLD and reference vessel diameter were 0.99 +/- 0.06 and 3.36 +/- 0,17 mm, respectively, providing a diameter stenosis of 71 +/- 2%, ICUS measurements (2.77 mm) of the reference vessel diameter (3.00 mm) were unaffected by the presence of the stent. Agreement of ICUS and QCA measurements (ICUS - QCA) was poorer in patients who had undergone balloon angioplasty (0.68 +/- 0.42 mm) than in patients who had stent implantation (-0,05 +/- 0.42 mm). In the 6-month follow-up of patients who had undergone implantation of highly radiopaque Cordis tantalum stent, assessment of restenosis was reliably quantified by QCA with the use of the MLD rather than the percent diameter stenosis. Although ICUS measurements are unaffected by the radiopaque stent, the mechanical problem of ICUS catheter wedging in stenoses of <1.00 mm and the substantial cost of ICUS catheters will restrict the widespread application of ICUS for the assessment of intrastent restenosis.
引用
收藏
页码:1135 / 1142
页数:8
相关论文
共 50 条
  • [11] Vestibular rehabilitation and 6-month follow-up using objective and subjective measures
    Meli, A
    Zimatore, G
    Badaracco, C
    De Angelis, E
    Tufarelli, D
    ACTA OTO-LARYNGOLOGICA, 2006, 126 (03) : 259 - 266
  • [12] EFFECTS OF INTRACORONARY NITROGLYCERIN ON LUMEN DIAMETER DURING EARLY FOLLOW-UP ANGIOGRAPHY AFTER CORONARY EXCIMER LASER ATHERECTOMY
    BAUMBACH, A
    HAASE, KK
    VOELKER, W
    MAUSER, M
    KARSCH, KR
    EUROPEAN HEART JOURNAL, 1991, 12 (06) : 726 - 731
  • [13] 6-MONTH CLINICAL AND ANGIOGRAPHIC FOLLOW-UP OF THE NEW LESS SHORTENING WALLSTENT IN NATIVE CORONARY-ARTERIES
    OZAKI, Y
    KEANE, D
    RUYGROK, P
    VANDERGIESSEN, WJ
    DEFEYTER, P
    CIRCULATION, 1995, 92 (08) : 377 - 377
  • [14] Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography
    de Feyter, PJ
    Kay, P
    Disco, C
    Serruys, PW
    CIRCULATION, 1999, 100 (17) : 1777 - 1783
  • [15] Micro stent I, initial results, and six months follow-up by quantitative coronary angiography
    Schalij, MJ
    Savalle, LH
    Tresukosol, D
    Jukema, JW
    Reiber, JHC
    Bruschke, AVG
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 43 (01): : 19 - 27
  • [16] Everolimus stent coating: promising procedural and 6-month angiographic and intravascular ultrasound follow-up results of the FUTURE I and II trial
    Grube, E
    Buellesfeld, L
    Mueller, R
    Staberock, M
    Schmidt, TH
    Selbach, G
    Gerckens, U
    EUROPEAN HEART JOURNAL, 2003, 24 : 267 - 267
  • [17] Overlapping Bioresorbable Coronary Devices: Immediate Results and 6-month Follow-up of the REPARA Registry
    Hernandez, Felipe
    Gaviria, Luis
    Bassaganyas, Joan
    Alonso Briales, Juan
    Oteo Dominguez, Juan Francisco
    Martinez-Romero, Pedro
    Andraka, Leire
    Serra, Antonio
    Rodriguez, Marcostomas
    Berenguer, Alberto
    Carvalho, Henrique
    Santos, Ricardo
    Costa, Joao
    Cabrera, Francisco Jimenez
    Bethencourt, Armando
    Garcia, Bruno
    Munoz, Juan Francisco
    Bosa, Francisco
    Elizaga, Jaime
    Garcia San Roman, Koldobika
    Hernandez, Rosana
    Ruiz Arroyo, Jose R.
    Martin-Moreiras, Javier
    HernandoRomero, LuisManuel
    Aguar Carrascosa, Pablo
    Teijeiro, Rodrigo
    Sanchez Insa, Esther
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B24 - B25
  • [18] Intracoronary radiation therapy for patients with in-stent restenosis: 6 month follow-up of a randomized clinical study
    Waksman, R
    White, LR
    Chan, RC
    Porrazo, MS
    Bass, BG
    Satler, LF
    Kent, KM
    Geirlach, LM
    Mehran, R
    Murphy, M
    Mintz, GS
    Leon, MB
    CIRCULATION, 1998, 98 (17) : 651 - 651
  • [19] Angiographic 6-month follow-up after eccentric excimer-laser coronary angioplasty (EccELCA) of diffuse 'in-stent'-restenosis
    Dahm, JB
    Kuon, E
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (6A): : 87P - 87P
  • [20] Clinical and 6-Month Follow-Up Study for Patients with Coronary Heart Disease Referred to TAXUS-LiberteTM-SR Stent Therapy
    Han, Xugeng
    Xu, Yawei
    Chen, Yanqing
    Li, Weiming
    Wei, Yidong
    Hou, Lei
    CIRCULATION, 2010, 122 (02) : E262 - E262