CORONARY LUMEN AT 6-MONTH FOLLOW-UP OF A NEW RADIOPAQUE CORDIS TANTALUM STENT USING QUANTITATIVE ANGIOGRAPHY AND INTRACORONARY ULTRASOUND

被引:25
|
作者
OZAKI, Y
KEANE, D
NOBUYOSHI, M
HAMASAKI, N
POPMA, JJ
SERRUYS, PW
机构
[1] ERASMUS UNIV ROTTERDAM, CTR THORAX, CATHETERIZAT LAB, 3000 DR ROTTERDAM, NETHERLANDS
[2] KOKURA MEM HOSP, DEPT CARDIOL, CATHETERIZAT LAB, KITAKYUSHU, FUKUOKA, JAPAN
[3] WASHINGTON HOSP CTR, DEPT INTERNAL MED, DIV CARDIOL, WASHINGTON, DC 20010 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1995年 / 76卷 / 16期
关键词
D O I
10.1016/S0002-9149(99)80322-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the reliability of geometric (edge-detection) quantitative coronary angiographic analysis (QCA) of restenosis within a new Cordis tantalum stent, QCA and intracoronary ultrasound (ICUS) measurements were compared in both an experimental restenosis model and in the clinical follow-up of patients, In the experimental series, Plexiglas(TM) phantom vessels with concentric stenosis channels ranging from 0.75 to 3.0 mm in diameter and with a reference diameter of 3.0 mm were imaged bath before and after their insertion in tantalum stents, In the clinical series, the agreement of QCA and ICUS measurements were studied in 23 patients who had undergone coronary implantation of the new tantalum stent and in 23 patients who had undergone balloon angioplasty 6 months previously, The reliability of QCA declined in the presence of the radiopaque stent (accuracy of QCA decreased from -0.07 to -0.12 mm), whereas the reliability of lumen measurements by ICUS was independent of the presence of the radiopaque stent (-0,12 and -0.13 mm), Without the stent, the average minimal luminal diameter (MLD) obtained by QCA of the 1,00 mm Plexiglas vessel was 1.00 +/- 0.01 mm, and the 3.00 mm reference vessel diameter was 2.81 +/- 0.05 mm, providing a 64 +/- 1% diameter stenosis, After introduction of the stent, the average MLD and reference vessel diameter were 0.99 +/- 0.06 and 3.36 +/- 0,17 mm, respectively, providing a diameter stenosis of 71 +/- 2%, ICUS measurements (2.77 mm) of the reference vessel diameter (3.00 mm) were unaffected by the presence of the stent. Agreement of ICUS and QCA measurements (ICUS - QCA) was poorer in patients who had undergone balloon angioplasty (0.68 +/- 0.42 mm) than in patients who had stent implantation (-0,05 +/- 0.42 mm). In the 6-month follow-up of patients who had undergone implantation of highly radiopaque Cordis tantalum stent, assessment of restenosis was reliably quantified by QCA with the use of the MLD rather than the percent diameter stenosis. Although ICUS measurements are unaffected by the radiopaque stent, the mechanical problem of ICUS catheter wedging in stenoses of <1.00 mm and the substantial cost of ICUS catheters will restrict the widespread application of ICUS for the assessment of intrastent restenosis.
引用
收藏
页码:1135 / 1142
页数:8
相关论文
共 50 条
  • [1] CORONARY LUMEN QUANTIFICATION AT 6 MONTH FOLLOW-UP OF THE NEW RADIOPAQUE CORDIS STENT - AN EXPERIMENTAL AND CLINICAL-STUDY USING GEOMETRIC (EDGE-DETECTION) QUANTITATIVE CORONARY ANGIOGRAPHY (QCA) AND INTRACORONARY ULTRASOUND (ICUS)
    OZAKI, Y
    KEANE, D
    HAMASAKI, N
    NOBUYOSHI, M
    CIRCULATION, 1995, 92 (08) : 1558 - 1558
  • [2] PIEZOELECTRIC LITHOTRIPSY OF RADIOPAQUE GALLSTONES - RESULTS AND 6-MONTH FOLLOW-UP
    HAN, JK
    CHOI, BI
    YOON, YB
    PARK, YH
    KIM, CW
    HAN, MC
    JOURNAL OF STONE DISEASE, 1993, 5 (02): : 89 - 95
  • [3] ULTRASOUND-GUIDED CORONARY STENT PLACEMENT WITHOUT WARFARIN ANTICOAGULATION - 6-MONTH CLINICAL FOLLOW-UP
    RUSSO, RJ
    SCHATZ, RA
    MORRIS, NB
    STEVENS, KM
    TEIRSTEIN, PS
    CIRCULATION, 1995, 92 (08) : 2592 - 2592
  • [4] (Δ) Initial clinical experience and 6-month follow-up by coronary computed tomography angiography of a new bioresorbable magnesium-based stent
    Ghafari, Chadi
    Brassart, Nicolas
    Brunner, Philippe
    Delmotte, Philippe
    Thayse, Kathleen
    Carlier, Stephane
    ACTA CARDIOLOGICA, 2019, 74 : 50 - 51
  • [5] 6-month angiographic follow-up of coronary stent placement in patients with acute myocardial infarction
    Hausleiter, J
    Walter, H
    Pache, J
    Dirschinger, J
    CIRCULATION, 1997, 96 (08) : 1826 - 1826
  • [6] Influence of planned 6-month follow-up angiography on late outcome after coronary angioplasty: A randomized study
    ten Berg, JM
    Kelder, JC
    Suttorp, MJ
    Verheugt, FWA
    Plokker, TWM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 17A - 18A
  • [7] Adjusting a polymer formulation for an optimal bioresorbable stent: a 6-month follow-up study
    Durand, Eric
    Lemitre, Mathilde
    Couty, Ludovic
    Sharkawi, Tahmer
    Brasselet, Camille
    Vert, Michel
    Lafont, Antoine
    EUROINTERVENTION, 2012, 8 (02) : 242 - 249
  • [8] Influence of planned 6-month follow-up angiography on late outcome after percutaneous coronary intervention: a randomized study
    ten Berg, JM
    Kelder, JC
    Suttorp, MJ
    Verheugt, FWA
    Plokker, HWM
    EUROPEAN HEART JOURNAL, 2001, 22 : 387 - 387
  • [9] A NEW EXPANDABLE INTRACORONARY TANTALUM (STRECKER) STENT - EARLY EXPERIMENTAL RESULTS AND FOLLOW-UP TO 12 MONTHS
    RIBEIRO, PA
    GALLO, R
    ANTONIUS, J
    MIMISH, L
    SRIRAM, R
    BIANCHI, S
    DURAN, CG
    AMERICAN HEART JOURNAL, 1993, 125 (02) : 501 - 510
  • [10] Screening renal artery angiography in hypertensive patients undergoing coronary angiography and 6-month follow-up after ad hoc percutaneous revascularization
    Rimoldi, Stefano F.
    de Marchi, Stefano F.
    Windecker, Stephan
    Meier, Bernhard
    Allemann, Yves
    JOURNAL OF HYPERTENSION, 2010, 28 (04) : 842 - 847