Tube Erosion Rate of Water Wall in a Commercial Circulating Fluidized Bed Combustor

被引:0
作者
Kim, Tae-Woo [1 ]
Choi, Jeong-Hoo [1 ]
Shun, Do-Won [2 ]
Son, Jae-Ek [2 ]
Jung, Bongjin [3 ]
Kim, Soo-Sup [4 ]
Kim, Sang-Done [5 ]
机构
[1] Konkuk Univ, Innovat Environm Technol Ctr, Dept Chem Engn, 1 Hwayang Dong, Seoul 143701, South Korea
[2] Korea Inst Energy Res, Daejeon 305343, South Korea
[3] Suwon Univ, Dept Environm Engn, Hwaseong Si, Gyeonggi Do, South Korea
[4] SK Chem Co, Ulsan 680160, South Korea
[5] Korea Adv Inst Sci & Technol, Dept Mol Biol & Chem Engn, Daejeon 305701, South Korea
来源
KOREAN CHEMICAL ENGINEERING RESEARCH | 2005年 / 43卷 / 04期
关键词
Tube Erosion Rate; Tube Erosion; Circulating Fluidized Bed; Combustor; Erosion;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The erosion rate of water wall tube has been measured and discussed in a commercial circulating fluidized bed combustor (200 ton steam/hr, 4.97 x 9.90 x 28.98 m height). Tube thickness was measured with ultrasonic method. Severe tube erosion rate was observed in the splash region on all waterwalls including wingwalls. The tube erosion rate increased after an initial decrease as height from the distributor increased. The difference of erosion rate among wing walls was found due to unbalanced distribution of gas and solid flow rates. The erosion rate of the wing wall increased as location of the wing wall became closer to the center of combustor crosssection.
引用
收藏
页码:525 / 530
页数:6
相关论文
共 12 条
[1]  
Han K. H., 1995, THESIS
[2]  
Holtzer G. J., 1991, P 11 INT C FLUID BED, P743
[3]  
Hou P. Y., 1999, P 15 INT C FLUID BED
[4]  
Lindsley B. A., 1993, P 1993 INT C FLUID B, P803
[5]  
Ninham A. J., 1989, P 10 INT C FLUID BED, P583
[6]  
Rogers W. A., 1993, P 1993 INT C FLUID B, P811
[7]  
Seitzinger D. L., 1995, P 13 INT C FLUID BED, P585
[8]  
Sethi V. K., 1989, P 10 INT C FLUID BED, P563
[9]  
STRINGER J, 1991, P 11 INT C FLUID BED, P589
[10]  
Vincent R. Q., 1989, P 10 INT C FLUID BED, P927