COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING

被引:1938
作者
BLAND, JM [1 ]
ALTMAN, DG [1 ]
机构
[1] IMPERIAL CANC RES FUND,MED STAT LAB,LONDON WC2,ENGLAND
来源
LANCET | 1995年 / 346卷 / 8982期
关键词
D O I
10.1016/S0140-6736(95)91748-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
When comparing a new method of measurement with a standard method, one of the things we want to know is whether the difference between the measurements by the two methods is related to the magnitude of the measurement. A plot of the difference against the standard measurement is sometimes suggested, but this will always appear to show a relation between difference and magnitude when there is none. A plot of the difference against the average of the standard and new measurements is unlikely to mislead in this way. We show this theoretically and by a practical example.
引用
收藏
页码:1085 / 1087
页数:3
相关论文
共 7 条
[1]   THE HIDDEN EFFECT OF TIME [J].
ALTMAN, DG ;
ROYSTON, JP .
STATISTICS IN MEDICINE, 1988, 7 (06) :629-637
[2]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[3]  
Bland J. M., 1992, CURRENT CONTENTS CM, VCM20, P8
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   FINGER SYSTOLIC PRESSURE - ITS USE IN SCREENING FOR HYPERTENSION AND MONITORING [J].
CLOSE, A ;
HAMILTON, G ;
MURISS, S .
BRITISH MEDICAL JOURNAL, 1986, 293 (6550) :775-778
[6]  
KRINGLE RO, 1994, TIETZ TXB CLIN CHEM, P384
[7]  
1984, CLIN LAB HAEMATOL, V6, P69