Hybrid Thoracic Stent Graft Repair of a Complex Type B Aortic Dissection in a Patient Who Presented Three Weeks After Repair of a Type A Aortic Dissection

被引:0
作者
Gaur, Puja [1 ]
Kasirajan, Karthikeshwar [2 ]
Miller, Daniel L. [3 ]
Vassiliades, Thomas A., Jr. [3 ]
机构
[1] Emory Univ, Sch Med, Div Gen Surg, Atlanta, GA USA
[2] Emory Univ, Sch Med, Div Cardiothorac Surg, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Div Vasc Surg, Atlanta, GA USA
关键词
Aortic dissection; Hybrid repair; Thoracic stent graft; False lumen aneurysm;
D O I
10.1097/imi.0b013e3181916602
中图分类号
R61 [外科手术学];
学科分类号
摘要
Long-term management after repair of a type A aortic dissection includes aggressive medical therapy and routine surveillance with serial imaging to ensure thrombosis of the false lumen. Retained patency of the false lumen can lead to either the development of a false lumen aneurysm with a subsequent rupture or extension of dissection. Typically such events occur late, usually months after repair, and are treated with either a conventional one-stage open thoracoabdominal repair or a two-stage "elephant trunk" procedure. However, most patients who undergo such procedures experience major complications and the procedure-related mortality rate is high. We present a unique case of a 61-year-old woman who presented with a ruptured type B aortic dissection 3 weeks after repair of a type A aortic dissection. She underwent an emergent thoracotomy and primary repair of the ruptured aorta followed by concomitant arch debranching and thoracic stent graft placement. Simultaneous surgical debranching with a median sternotomy and endovascular repair with stent grafts is an attractive hybrid approach in patients who present with an acute rupture of a false lumen aneurysm soon after initial repair of an aortic dissection, a situation in which a conventional repair is not feasible. This report emphasizes that hybrid thoracic stent graft repair should be considered for such high-risk patients in the near future as it offers them relatively lower morbidity and mortality compared with what is seen with conventional repairs.
引用
收藏
页码:158 / 160
页数:3
相关论文
共 6 条
[1]   The hybrid elephant trunk procedure: A single-stage repair of an ascending, arch, and descending thoracic aortic aneurysm [J].
Azizzadeh, Ali ;
Estrera, Anthony L. ;
Porat, Eyal E. ;
Madsen, Kenneth R. ;
Safi, Hazim J. .
JOURNAL OF VASCULAR SURGERY, 2006, 44 (02) :404-407
[2]   Off-pump management of aortic arch aneurysm by using an endovascular thoracic stent graft [J].
Dietl, CA ;
Kasirajan, K ;
Pett, SB ;
Wernly, JA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (04) :1181-1183
[3]   The International Registry of Acute Aortic Dissection (IRAD) - New insights into an old disease [J].
Hagan, PG ;
Nienaber, CA ;
Isselbacher, EM ;
Bruckman, D ;
Karavite, DJ ;
Russman, PL ;
Evangelista, A ;
Fattori, R ;
Suzuki, T ;
Oh, JK ;
Moore, AG ;
Malouf, JF ;
Pape, LA ;
Gaca, C ;
Sechtem, U ;
Lenferink, S ;
Deutsch, HJ ;
Diedrichs, H ;
Robles, JMY ;
Llovet, A ;
Gilon, D ;
Das, SK ;
Armstrong, WF ;
Deeb, GM ;
Eagle, KA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (07) :897-903
[4]   Single-stage reoperative repair of chronic type A aortic dissection by means of the arch-first technique [J].
Kouchoukos, NT ;
Masetti, P ;
Rokkas, CK ;
Murphy, SF .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (03) :578-582
[5]   Reevaluating the need for left subclavian artery revascularization with thoracic endovascular aortic repair [J].
Reece, T. Brett ;
Gazoni, Leo M. ;
Cherry, Kenneth J. ;
Peeler, Benjamin B. ;
Dake, Michael ;
Matsumoto, Alan H. ;
Angle, John ;
Kron, Irving L. ;
Tribble, Curtis G. ;
Kern, John A. .
ANNALS OF THORACIC SURGERY, 2007, 84 (04) :1201-1205
[6]   Endovascular stent grafting of the descending thoracic aorta after arch repair in acute type A dissection [J].
Yano, H ;
Ishimaru, S ;
Kawaguchi, S ;
Obitsu, Y .
ANNALS OF THORACIC SURGERY, 2002, 73 (01) :288-291