The comparison of stroke volume variation with central venous pressure in predicting fluid responsiveness in septic patients with acute circulatory failure

被引:29
作者
Angappan, Santhalakshmi [1 ]
Parida, Satyen [1 ]
Vasudevan, Arumugam [1 ]
Badhe, Ashok Shankar [1 ]
机构
[1] JIPMER, Dept Anesthesiol & Crit Care, Pondicherry, India
关键词
Acute circulatory failure; central venous pressure; fluid responsiveness; sepsis; stroke volume variation;
D O I
10.4103/0972-5229.160278
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The present study was designed to investigate the efficacy of stroke volume variation (SVV) in predicting fluid responsiveness and compare it to traditional measures of volume status assessment like central venous pressure (CVP). Methods: Forty-five mechanically ventilated patients in sepsis with acute circulatory failure. Patients were not included when they had atrial fibrillation, other severe arrhythmias, permanent pacemaker, or needed mechanical cardiac support. Furthermore, excluded were patients with hypoxemia and a CVP > 12. Patients received volume expansion in the form of 500 ml of 6% hydroxyethyl starch. Results: The volume expansion-induced increase in cardiac index (CI) was > 15% in 29 patients (labeled responders) and <15% in 16 patients (labeled nonresponders). Before volume expansion, SVV was higher in responders than in nonresponders. Receiver operating characteristic curves analysis showed that SVV was a more accurate indicator of fluid responsiveness than CVP. Before volume expansion, an SVV value of 13% allowed discrimination between responders and nonresponders with a sensitivity of 78% and a specificity of 89%. Volume expansion-induced changes in CI weakly and positively correlated with SVV before volume expansion. Volume expansion decreased SVV from 18.86 +/- 4.35 to 7.57 +/- 1.80 and volume expansion-induced changes in SVV moderately correlated with volume expansion-induced changes in CI. Conclusions: When predicting fluid responsiveness in mechanically ventilated patients in septic shock, SVV is more effective than CVP. Nevertheless, the overall correlation of baseline SVV with increases in CI remains poor. Trends in SVV, as reflected by decreases with volume replacement, seem to correlate much better with increases in CI.
引用
收藏
页码:394 / 400
页数:7
相关论文
共 20 条
[1]   Septic shock [J].
Astiz, ME ;
Rackow, EC .
LANCET, 1998, 351 (9114) :1501-1505
[2]   Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation [J].
Biais, M. ;
Nouette-Gaulain, K. ;
Cottenceau, V. ;
Revel, P. ;
Sztark, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) :761-768
[3]   AMERICAN-COLLEGE OF CHEST PHYSICIANS SOCIETY OF CRITICAL CARE MEDICINE CONSENSUS CONFERENCE - DEFINITIONS FOR SEPSIS AND ORGAN FAILURE AND GUIDELINES FOR THE USE OF INNOVATIVE THERAPIES IN SEPSIS [J].
BONE, RC ;
BALK, RA ;
CERRA, FB ;
DELLINGER, RP ;
FEIN, AM ;
KNAUS, WA ;
SCHEIN, RMH ;
SIBBALD, WJ ;
ABRAMS, JH ;
BERNARD, GR ;
BIONDI, JW ;
CALVIN, JE ;
DEMLING, R ;
FAHEY, PJ ;
FISHER, CJ ;
FRANKLIN, C ;
GORELICK, KJ ;
KELLEY, MA ;
MAKI, DG ;
MARSHALL, JC ;
MERRILL, WW ;
PRIBBLE, JP ;
RACKOW, EC ;
RODELL, TC ;
SHEAGREN, JN ;
SILVER, M ;
SPRUNG, CL ;
STRAUBE, RC ;
TOBIN, MJ ;
TRENHOLME, GM ;
WAGNER, DP ;
WEBB, CD ;
WHERRY, JC ;
WIEDEMANN, HP ;
WORTEL, CH .
CRITICAL CARE MEDICINE, 1992, 20 (06) :864-874
[4]   The Ability of Stroke Volume Variations Obtained with Vigileo/FloTrac System to Monitor Fluid Responsiveness in Mechanically Ventilated Patients [J].
Cannesson, Maxime ;
Musard, Henri ;
Desebbe, Olivier ;
Boucau, Cecile ;
Simon, Remi ;
Henaine, Roland ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2009, 108 (02) :513-517
[5]  
Daihua Y, 2012, J CRIT CARE, V27, P416
[6]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[7]   Comparison of commonly used clinical indicators of hypovolaemia with gastrointestinal tonometry [J].
HamiltonDavies, C ;
Mythen, MG ;
Salmon, JB ;
Jacobson, D ;
Shukla, A ;
Webb, AR .
INTENSIVE CARE MEDICINE, 1997, 23 (03) :276-281
[8]   Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects [J].
Kumar, A ;
Anel, R ;
Bunnell, E ;
Habet, K ;
Zanotti, S ;
Marshall, S ;
Neumann, A ;
Ali, A ;
Cheang, M ;
Kavinsky, C ;
Parrillo, JE .
CRITICAL CARE MEDICINE, 2004, 32 (03) :691-699
[9]   Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively [J].
Lahner, D. ;
Kabon, B. ;
Marschalek, C. ;
Chiari, A. ;
Pestel, G. ;
Kaider, A. ;
Fleischmann, E. ;
Hetz, H. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (03) :346-351
[10]  
Liu H., 2010, INTERNET J ANESTHESI, V22, P1