COMPARISON OF CELL VIABILITY PROBES COMPATIBLE WITH FIXATION AND PERMEABILIZATION FOR COMBINED SURFACE AND INTRACELLULAR STAINING IN FLOW-CYTOMETRY

被引:106
作者
OBRIEN, MC [1 ]
BOLTON, WE [1 ]
机构
[1] COULTER CORP, COULTER TECHNOL CTR, IMMUNOL RES & TECHNOL, MIAMI, FL 33116 USA
来源
CYTOMETRY | 1995年 / 19卷 / 03期
关键词
VIABILITY; CELL DEATH; NECROSIS; APOPTOSIS; FLOW CYTOMETRY;
D O I
10.1002/cyto.990190308
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dead cells represent a significant source of interference in the flow cytometric analysis of viable cells primarily due to nonspecific uptake of probes, increased autofluorescence, and altered antigen expression and DNA content. Traditional methods of dead cell exclusion, based on light scatter or uptake of dyes such as propidium iodide (PI) or fluorescein diacetate (FDA), are appropriate for the analysis of fresh, relatively homogeneous samples, However, they are incompatible with the development in this laboratory of a solid tumor monoclonal antibody panel incorporating combined surface and intracellular staining: Light scatter is unreliable in heterogeneous samples such as solid tumors, and most of the widely used viability probes are incompatible, due to weak or reversible binding, with the use of permeabilizing agents for intracellular staining. To determine the best viability marker for inclusion in the solid tumor panel, we compared cultured tells held under hypoxic conditions for up to 15 days after harvest, stained with eight viability probes, and processed according to the solid tumor panel procedure (unprocessed cells from each day, stained with PI, were used as standards), The viability probes included PI (in processed and unprocessed samples); 7-aminoactinomycin D (7-AAD); TO-PRO-3; laser dye styryl (LDS)-751; ethidium monoazide (EMA);and actin, cytokeratin, and tubulin indirectly labelled with sheep-alpha-mouse-FITC (SAM-FITC), The selection criteria for the best viability probe included broad cell type specificity: low nonspecific staining of live cells, specific staining of dead cells strong enough to withstand the permeabilization procedure, high signal-to-noise ratio throughout the time course, and compatibility with the four other fluorescent probes making up the turner antibody panel. TO-PRO-3, LDS-751, and PI (in processed cells) stained both live and dead cells indiscriminately, Actin-SAM-FITC, EMA, and 7-AAD did not display sufficiently high signal-to-noise ratios over the entire time course. Cytokeratin-SAM-FITC was acceptable in every respect other than its specificity only for cells of epithelial origin, Tubulin-SAM-FITC alone satisfied all the criteria and was selected for inclusion in the monoclonal antibody panel as a viability probe. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:243 / 255
页数:13
相关论文
共 34 条
  • [1] THE USE OF FLOW-CYTOMETRY FOR THE INVESTIGATION OF CELL-DEATH
    AFANASYEV, VN
    KOROL, BA
    MATYLEVICH, NP
    PECHATNIKOV, VA
    UMANSKY, SR
    [J]. CYTOMETRY, 1993, 14 (06): : 603 - 609
  • [2] EFFECTS OF HYPOXIA ON MORPHOLOGICAL AND BIOCHEMICAL CHARACTERISTICS OF RENAL EPITHELIAL-CELL AND TUBULE CULTURES
    ALLEN, J
    WINTERFORD, C
    AXELSEN, RA
    GOBE, GC
    [J]. RENAL FAILURE, 1992, 14 (04) : 453 - 460
  • [3] BAUER KD, 1986, CANCER RES, V46, P2428
  • [4] EXPRESSION OF PROLIFERATION ASSOCIATED ANTIGENS IN THE CELL-CYCLE OF SYNCHRONIZED MAMMALIAN-CELLS
    BOLTON, WE
    MIKULKA, WR
    HEALY, CG
    SCHMITTLING, RJ
    KENYON, NS
    [J]. CYTOMETRY, 1992, 13 (02): : 117 - 126
  • [5] SINGLE UV EXCITATION OF HOECHST-33342 AND ETHIDIUM-BROMIDE FOR SIMULTANEOUS CELL-CYCLE ANALYSIS AND VIABILITY DETERMINATIONS ON IN-VITRO CULTURES OF MURINE B-LYMPHOCYTES
    BOLTZ, RC
    FISCHER, PA
    WICKER, LS
    PETERSON, LB
    [J]. CYTOMETRY, 1994, 15 (01): : 28 - 34
  • [6] CLEVENGER CV, 1993, CLIN FLOW CYTOMETRY, P157
  • [7] COTTER TG, 1992, ANTICANCER RES, V12, P773
  • [8] FEATURES OF APOPTOTIC CELLS MEASURED BY FLOW-CYTOMETRY
    DARZYNKIEWICZ, Z
    BRUNO, S
    DELBINO, G
    GORCZYCA, W
    HOTZ, MA
    LASSOTA, P
    TRAGANOS, F
    [J]. CYTOMETRY, 1992, 13 (08): : 795 - 808
  • [9] ANALYTICAL CYTOMETRIC APPROACHES TO HETEROGENEOUS CELL-POPULATIONS IN SOLID TUMORS - A REVIEW
    DETHLEFSEN, LA
    BAUER, KD
    RILEY, RM
    [J]. CYTOMETRY, 1980, 1 (02): : 89 - 97
  • [10] ANALYSIS AND DISCRIMINATION OF NECROSIS AND APOPTOSIS (PROGRAMMED CELL-DEATH) BY MULTIPARAMETER FLOW-CYTOMETRY
    DIVE, C
    GREGORY, CD
    PHIPPS, DJ
    EVANS, DL
    MILNER, AE
    WYLLIE, AH
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1992, 1133 (03) : 275 - 285