EVALUATION OF A MODIFIED COMMERCIAL GRAPHITE-FURNACE FOR REDUCTION OF ISOBARIC INTERFERENCES IN ARGON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY

被引:56
作者
CAREY, JM
EVANS, EH
CARUSO, JA
SHEN, WL
机构
[1] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
[2] US FDA,NATL FORENS CHEM CTR,CINCINNATI,OH 45202
关键词
D O I
10.1016/0584-8547(91)80175-3
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A modified Perkin-Elmer HGA 300 graphite furnace has been investigated for sample introduction into inductively coupled plasma mass spectrometry (ICP-MS). Its application for the reduction of matrix related isobaric interferences at m/z 56 (ArO+ and the major isotope of Fe) and m/z 75 (ArCl+ and monoisotopic As) was studied. Optimization of operating conditions for the ETV instrument, including carrier flow, drying temperature and coolant flow, was performed. Absolute detection limits were found to be 1.5 pg for As and 0.2 pg for Fe, with reproducibility between 5 and 8% RSD for ten 10-mu-l sample injections of 10 ng g-1 Fe and As. Linear responses were found to be three orders of magnitude for Fe and four orders of magnitude for As.
引用
收藏
页码:1711 / 1721
页数:11
相关论文
共 29 条
[1]   STUDIES OF A RADIO-FREQUENCY INDUCTIVELY COUPLED ARGON PLASMA FOR OPTICAL EMISSION SPECTROMETRY .3. INTERFERENCE EFFECTS UNDER COMPROMISE CONDITIONS FOR SIMULTANEOUS MULTI-ELEMENT ANALYSIS [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1976, 31 (06) :355-375
[2]   SAMPLE INTRODUCTION TECHNIQUES FOR ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A875-+
[3]   SAMPLE INTRODUCTION - THE ACHILLES HEEL OF ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A786-&
[4]   STUDIES IN THE DETERMINATION OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
DATE, AR ;
CHEUNG, YY .
ANALYST, 1987, 112 (11) :1531-1540
[5]  
DOUGLAS DJ, 1985, PROG ANAL ATOM SPECT, V8, P1
[8]   OPTICAL EMISSION SPECTROMETRY WITH AN INDUCTIVELY COUPLED RADIOFREQUENCY ARGON PLASMA SOURCE AND SAMPLE INTRODUCTION WITH A GRAPHITE ROD ELECTROTHERMAL VAPORIZATION DEVICE .1. INSTRUMENTAL ASSEMBLY AND PERFORMANCE-CHARACTERISTICS [J].
GUNN, AM ;
MILLARD, DL ;
KIRKBRIGHT, GF .
ANALYST, 1978, 103 (1231) :1066-1073
[9]   RELATIVE MERITS OF 2 METHODS OF SAMPLE INTRODUCTION IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - ELECTROTHERMAL VAPORIZATION AND DIRECT SAMPLE INSERTION [J].
HALL, GEM ;
PELCHAT, JC ;
BOOMER, DW ;
POWELL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :791-797
[10]   MASS-SPECTROMETRY OF INDUCTIVELY COUPLED PLASMAS [J].
HOUK, RS .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :A97-&