ACCURACY AND REPRODUCIBILITY OF QUANTITATIVE CORONARY ARTERIOGRAPHY USING 6 AND 8 FRENCH CATHETERS WITH CINE ANGIOGRAPHIC ACQUISITION

被引:16
作者
ELLIS, SG
PINTO, IMF
MCGILLEM, MJ
DEBOE, SF
LEFREE, MT
MANCINI, GBJ
机构
[1] UNIV MICHIGAN HOSP,DEPT INTERNAL MED,DIV CARDIOL,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,SCH MED,VET ADM MED CTR,ANN ARBOR,MI 48104
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1991年 / 22卷 / 01期
关键词
QUANTITATIVE ARTERIOGRAPHY; ANGIOGRAPHY;
D O I
10.1002/ccd.1810220113
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the suitability of 6 French catheters for quantitative coronary arteriography, the relative accuracy and reproducibility of one type of these catheters was compared to that obtained with standard 8 French catheters in 20 stenoses. Duplicate injections with polyurethane 6 French catheters were obtained using hand and power injection technique with cineangiographic acquisition (four 6 French catheter injections total per stenosis). Measurements of both percent diameter stenosis and absolute dimensions were compared to those obtained with hand injection and cine acquisition using 8 French catheters as a "gold standard." While the reproducibility of dimension determination with the 6 French catheter was generally similar to that obtained with the 8 French catheter (0.27 +/- 0.23 mm for absolute diameter and 8.1 +/- 7.4% for percent diameter stenosis), accuracy was significantly less for the 6 French catheter for measurement of absolute dimensions. Thus, while apparently well suited for serial measurements of the same stenoses, 6 French catheters may not be as accurate in the determination of absolute artery dimensions as 8 French catheters.
引用
收藏
页码:52 / 55
页数:4
相关论文
共 18 条
[1]   ARTERIOGRAPHIC ASSESSMENT OF CORONARY ATHEROSCLEROSIS - REVIEW OF CURRENT METHODS, THEIR LIMITATIONS, AND CLINICAL-APPLICATIONS [J].
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
ARTERIOSCLEROSIS, 1982, 2 (01) :2-15
[2]   QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION [J].
BROWN, BG ;
BOLSON, E ;
FRIMER, M ;
DODGE, HT .
CIRCULATION, 1977, 55 (02) :329-337
[3]   USE OF 5 FRENCH CATHETERS FOR CARDIAC-CATHETERIZATION AND CORONARY ANGIOGRAPHY - A CRITICAL-REVIEW [J].
BROWN, RIG ;
MACDONALD, AC .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1987, 13 (03) :214-217
[4]   VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS [J].
DEROUEN, TA ;
MURRAY, JA ;
OWEN, W .
CIRCULATION, 1977, 55 (02) :324-328
[5]   OPTIMAL DETECTION OF THE PROGRESSION OF CORONARY-ARTERY DISEASE - COMPARISON OF METHODS SUITABLE FOR RISK FACTOR INTERVENTION TRIALS [J].
ELLIS, S ;
SANDERS, W ;
GOULET, C ;
MILLER, R ;
CAIN, KC ;
LESPERANCE, J ;
BOURASSA, MG ;
ALDERMAN, EL .
CIRCULATION, 1986, 74 (06) :1235-1242
[6]  
ELLIS SG, 1987, CIRCULATION, V76, P369
[7]   THE VALUE OF LESION CROSS-SECTIONAL AREA DETERMINED BY QUANTITATIVE CORONARY ANGIOGRAPHY IN ASSESSING THE PHYSIOLOGIC SIGNIFICANCE OF PROXIMAL LEFT ANTERIOR DESCENDING CORONARY ARTERIAL STENOSES [J].
HARRISON, DG ;
WHITE, CW ;
HIRATZKA, LF ;
DOTY, DB ;
BARNES, DH ;
EASTHAM, CL ;
MARCUS, ML .
CIRCULATION, 1984, 69 (06) :1111-1119
[8]   RETHROMBOSIS AFTER REPERFUSION WITH STREPTOKINASE - IMPORTANCE OF GEOMETRY OF RESIDUAL LESIONS [J].
HARRISON, DG ;
FERGUSON, DW ;
COLLINS, SM ;
SKORTON, DJ ;
ERICKSEN, EE ;
KIOSCHOS, JM ;
MARCUS, ML ;
WHITE, CW .
CIRCULATION, 1984, 69 (05) :991-999
[9]  
KLINKE WP, 1989, CLIN RES, V37, pA95
[10]   AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD [J].
MANCINI, GBJ ;
SIMON, SB ;
MCGILLEM, MJ ;
LEFREE, MT ;
FRIEDMAN, HZ ;
VOGEL, RA .
CIRCULATION, 1987, 75 (02) :452-460