Clinical Outcomes of Tibial Components with Modular Stems Used in Primary TKA

被引:14
作者
Durig, Nicole [1 ]
Pace, Thomas [2 ]
Broome, Brandon [3 ]
Osuji, Obi [3 ]
Harman, Melinda K. [1 ]
机构
[1] Clemson Univ, Dept Bioengn, Rhodes Engn Res Ctr 301, Clemson, SC 29634 USA
[2] Univ South Carolina, Sch Med Greenville, Greenville, SC 29605 USA
[3] Steadman Hawkins Clin Carolinas, Greenville, SC 29615 USA
关键词
D O I
10.1155/2014/651279
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Due to the known potential for fretting and corrosion at modular junctions in orthopaedic implants, this retrospective study evaluated radiographic and clinical outcomes of 85 primary TKA patients implanted with modular stemmed tibial components and followed up for an average of 82 months. There was low incidence of tibial radiolucent lines, excellent functional outcomes, and no complications associated with stem modularity. The findings were comparable to the historical control study involving 107 TKA with a nonmodular tibial stem design. When using surface cemented tibial components combined with a constrained polyethylene bearing, modular stems appear to be a viable option for primary TKA when adequate fixation and rotational stability are maintained.
引用
收藏
页数:6
相关论文
共 45 条
[31]   Revision total knee arthroplasty with modular cemented stems - Long-term follow-up [J].
Mabry, Tad M. ;
Vessely, Michael B. ;
Schleck, Cathy D. ;
Harmsen, William Scott ;
Berry, Daniel J. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (06) :100-105
[32]   Adverse Local Tissue Response Lesion of the Knee Associated With Morse Taper Corrosion [J].
McMaster, William C. ;
Patel, Jay .
JOURNAL OF ARTHROPLASTY, 2013, 28 (02) :375.e5-375.e8
[33]   Long-term clinical and radiographic results of a pegged tibial baseplate in primary total knee arthroplasty [J].
Miller, CW ;
Pettygrow, R .
JOURNAL OF ARTHROPLASTY, 2001, 16 (01) :70-75
[34]   Primary total knee arthroplasty using the genesis total knee arthroplasty system - 3- to 6-year follow-up study of 105 knees [J].
Mokris, JG ;
Smith, SW ;
Anderson, SE .
JOURNAL OF ARTHROPLASTY, 1997, 12 (01) :91-98
[35]   Posterior cruciate ligament substitution is not essential for excellent postoperative outcomes in total knee arthroplasty [J].
Parsley, Brian S. ;
Conditt, Michael A. ;
Bertolusso, Roberto ;
Noble, Philip C. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (06) :127-131
[36]  
Patel A. R., 2012, J BONE JOINT SURG, V2, P1
[37]   Addition of a short central extension to surface cemented tibial trays in primary TKA:: An in vitro study of the effect on initial fixation stability and its relationship to supporting bone density [J].
Perez-Blanca, A. ;
Prado, M. ;
Ezquerro, F. ;
Montanez, E. ;
Espejo, A. .
CLINICAL BIOMECHANICS, 2008, 23 (04) :483-492
[38]   Stemmed Implants Improve Stability in Augmented Constrained Condylar Knees [J].
Rawlinson, Jeremy J. ;
Closkey, Robert F., Jr. ;
Davis, Nicole ;
Wright, Timothy M. ;
Windsor, Russell .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) :2639-2643
[39]   Cancellous bone strains indicate efficacy of stem augmentation in constrained condylar knees [J].
Rawlinson, JJ ;
Peters, LE ;
Campbell, DA ;
Windsor, R ;
Wright, TM ;
Bartel, DL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :107-116
[40]   In Vivo Severe Corrosion and Hydrogen Embrittlement of Retrieved Modular Body Titanium Alloy Hip-Implants [J].
Rodrigues, Danieli C. ;
Urban, Robert M. ;
Jacobs, Joshua J. ;
Gilbert, Jeremy L. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 88B (01) :206-219