Clinical Outcomes of Tibial Components with Modular Stems Used in Primary TKA

被引:14
作者
Durig, Nicole [1 ]
Pace, Thomas [2 ]
Broome, Brandon [3 ]
Osuji, Obi [3 ]
Harman, Melinda K. [1 ]
机构
[1] Clemson Univ, Dept Bioengn, Rhodes Engn Res Ctr 301, Clemson, SC 29634 USA
[2] Univ South Carolina, Sch Med Greenville, Greenville, SC 29605 USA
[3] Steadman Hawkins Clin Carolinas, Greenville, SC 29615 USA
关键词
D O I
10.1155/2014/651279
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Due to the known potential for fretting and corrosion at modular junctions in orthopaedic implants, this retrospective study evaluated radiographic and clinical outcomes of 85 primary TKA patients implanted with modular stemmed tibial components and followed up for an average of 82 months. There was low incidence of tibial radiolucent lines, excellent functional outcomes, and no complications associated with stem modularity. The findings were comparable to the historical control study involving 107 TKA with a nonmodular tibial stem design. When using surface cemented tibial components combined with a constrained polyethylene bearing, modular stems appear to be a viable option for primary TKA when adequate fixation and rotational stability are maintained.
引用
收藏
页数:6
相关论文
共 45 条
[1]  
Ahn J-M, 2010, J ARTHROPLASTY, V25, DOI [10.1016/j.arth.2009.06.014, DOI 10.1016/J.ARTH.2009.06.014]
[2]   Contemporary Cruciate-Retaining Total Knee Arthroplasty with a Pegged Tibial Baseplate Results at a Minimum of Ten Years [J].
Barrington, John W. ;
Sah, Alexander ;
Malchau, Henrik ;
Burke, Dennis W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (04) :874-878
[3]   Tibial component fixation in total knee arthroplasty - A comparison of pegged and stemmed designs [J].
Bertin, Kim C. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (05) :670-678
[4]   A mobile-bearing knee prosthesis can reduce strain at the proximal tibia [J].
Bottlang, Michael ;
Erne, Oliver K. ;
Lacatusu, Elvis ;
Sommers, Mark B. ;
Kessler, Oliver .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (447) :105-111
[5]  
BOURNE RB, 1986, CLIN ORTHOP RELAT R, P95
[6]  
BROOKS PJ, 1984, CLIN ORTHOP RELAT R, P302
[7]   Metal is not inert: Role of metal ions released by biocorrosion in aseptic loosening-Current concepts [J].
Cadosch, Dieter ;
Chan, Erwin ;
Gautschi, Oliver P. ;
Filgueira, Luis .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 91A (04) :1252-1262
[8]   Full and surface tibial cementation in total knee arthroplasty: A biomechanical investigation of stress distribution and remodeling in the tibia [J].
Cawley, Derek T. ;
Kelly, Nicola ;
Simpkin, Andrew ;
Shannon, Fintan J. ;
McGarry, J. Patrick .
CLINICAL BIOMECHANICS, 2012, 27 (04) :390-397
[9]   The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement [J].
Chong, Desmond Y. R. ;
Hansen, Ulrich N. ;
van der Venne, Rene ;
Verdonschot, Nico ;
Amis, Andrew A. .
JOURNAL OF BIOMECHANICS, 2011, 44 (05) :948-954
[10]   The influence of different tibial stem designs in load sharing and stability at the cement-bone interface in revision TKA [J].
Completo, A. ;
Simoes, J. A. ;
Fonseca, F. ;
Oliveira, M. .
KNEE, 2008, 15 (03) :227-232