INITIAL STABILITY OF UNCEMENTED HIP STEMS - AN IN-VITRO PROTOCOL TO MEASURE TORSIONAL INTERFACE MOTION

被引:56
作者
HARMAN, MK
TONI, A
CRISTOFOLINI, L
VICECONTI, M
机构
[1] RIZZOLI ORTHOPAED HOSP, BIOMAT TECHNOL LAB, I-40136 BOLOGNA, ITALY
[2] UNIV BOLOGNA, ORTHOPAED CLIN, BOLOGNA, ITALY
[3] UNIV BOLOGNA, FAC ENGN, DEPT ELECTR, BOLOGNA, ITALY
关键词
UNCEMENTED; TORSION; STABILITY; MICROMOTION; HIP; STEM; THR; BIOMECHANICS;
D O I
10.1016/1350-4533(95)95705-F
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The difficulty in quantitatively assessing the inherent variables of surgical stem insertion and interfemur differences continues to be a problem in experimental methodologies which assess hip stem stability. An in-vitro torsional stability protocol was developed which limited the mechanical testing variability and provided a reproducible micromotion measurement of an uncemented stem in synthetic composite femurs. Using a controlled mechanical stem insertion resulted in less interfemur variability within each group with the coefficient of variation being reduced from 35% overall to less than 20%. Femurs with shallow stem insertion depths had significantly larger micromotion than femurs having deep stem insertion depths. The sensitivity of the experimental protocol and the synthetic composite femurs to the varied functional behaviour of three different stem designs was demonstrated. The stem with a hollowed anterior-to-posterior proximal section experienced significantly more motion than the two stems with full proximal sections, reinforcing the need for proximal contact to ensure minimal micromotion in torsional loading.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 47 条
[1]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[2]  
BIANCO PT, 1989, 1989 P BIOM S, P297
[3]   MICROMOTION OF CEMENTED AND UNCEMENTED FEMORAL COMPONENTS [J].
BURKE, DW ;
OCONNOR, DO ;
ZALENSKI, EB ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :33-37
[4]  
BURKE DW, 1991, 37TH ANN M ORTH RES, P103
[5]   THE EFFECT OF FEMORAL STEM GEOMETRY ON INTERFACE MOTION IN UNCEMENTED POROUS-COATED TOTAL HIP PROSTHESES - COMPARISON OF STRAIGHT-STEM AND CURVED-STEM DESIGNS [J].
CALLAGHAN, JJ ;
FULGHUM, CS ;
GLISSON, RR ;
STRANNE, SK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :839-848
[6]  
CHARNLEY J, 1979, LOW FRICTION ANTHR H, P112
[7]   ROLE OF LOADS AND PROSTHESIS MATERIAL PROPERTIES ON THE MECHANICS OF THE PROXIMAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY [J].
CHEAL, EJ ;
SPECTOR, M ;
HAYES, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (03) :405-422
[8]  
Clarke H J, 1992, J Arthroplasty, V7, P235, DOI 10.1016/0883-5403(92)90042-O
[9]   BIOMECHANICAL INVESTIGATION OF HUMAN HIP [J].
CROWNINSHIELD, RD ;
JOHNSTON, RC ;
ANDREWS, JG ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1978, 11 (1-2) :75-85
[10]   TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50