MAGNETIC-FIELD-GRADIENT-COIL SYSTEM FOR SOLID-STATE MAS AND CRAMPS NMR IMAGING

被引:19
作者
BUSZKO, M [1 ]
MACIEL, GE [1 ]
机构
[1] COLORADO STATE UNIV, DEPT CHEM, FT COLLINS, CO 80523 USA
关键词
D O I
10.1006/jmra.1994.1062
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The idea of combining cylindrical coils for producing a longitudinal gradient with respect to the MAS axis with quadrupole (straight wire) magnetic-field-gradient coils for producing two transverse gradients for 3D MAS and CRAMPS imaging has been demonstrated. A modified set of a double Maxwell pair and two sets of quadrupole (eight-wire) coils were combined in a compact way and adapted for a 5 mm MAS rotor, achieving gradients of high efficiency (4.3 and 2.9 G/cm A for longitudinal and transverse coils, respectively), low inductance (3.5 and 1.9 mu H, respectively), and very good linearity(1%). A 60 mu m spatial resolution in a TREV-CRAMPS imaging experiment on solid polyethylene oxide was demonstrated; gradient pulses of 12 mu s duration were generated by applying currents of 2.3 and 1.5 A to longitudinal and transverse coils, respectively. This magnetic-field-gradient-coil configuration could also be applied in other areas of NMR where time-dependent gradients are required. (C) 1994 Academic Press, Inc.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 59 条
[41]   TECHNIQUES FOR NMR IMAGING OF SOLIDS [J].
MILLER, JB .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1991, 10 (02) :59-64
[42]   USE OF A QUADRUPOLE COIL FOR NMR SPIN-ECHO DIFFUSION STUDIES [J].
ODBERG, G ;
ODBERG, L .
JOURNAL OF MAGNETIC RESONANCE, 1974, 16 (02) :342-347
[43]   TIME-REVERSAL EXPERIMENTS IN DIPOLAR-COUPLED SPIN SYSTEMS [J].
RHIM, WK ;
PINES, A ;
WAUGH, JS .
PHYSICAL REVIEW B, 1971, 3 (03) :684-&
[44]   MAGNET FIELD PROFILING - ANALYSIS AND CORRECTING COIL DESIGN [J].
ROMEO, F ;
HOULT, DI .
MAGNETIC RESONANCE IN MEDICINE, 1984, 1 (01) :44-65
[45]   CONDITIONS FOR GENERATING ROTATING GRADIENTS IN MAS NMR IMAGING [J].
SCHAUSS, G ;
BLUMICH, B ;
SPIESS, HW .
JOURNAL OF MAGNETIC RESONANCE, 1991, 95 (02) :437-441
[46]   DESIGN OPTIMIZATION OF MAIN, GRADIENT AND RF-FIELD COILS FOR MR IMAGING [J].
SIEBOLD, H .
IEEE TRANSACTIONS ON MAGNETICS, 1990, 26 (02) :841-846
[47]   GRADIENT FIELD-COILS FOR MR IMAGING WITH HIGH SPECTRAL PURITY [J].
SIEBOLD, H .
IEEE TRANSACTIONS ON MAGNETICS, 1990, 26 (02) :897-900
[48]   IMPROVING MAGNETIC-FIELD GRADIENT COILS FOR NMR IMAGING [J].
SUITS, BH ;
WILKEN, DE .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (08) :565-573
[49]   A MAGIC ECHO PULSE SEQUENCE FOR THE HIGH-RESOLUTION NMR-SPECTRA OF ABUNDANT SPINS IN SOLIDS [J].
TAKEGOSHI, K ;
MCDOWELL, CA .
CHEMICAL PHYSICS LETTERS, 1985, 116 (2-3) :100-104
[50]   MINIMUM INDUCTANCE COILS [J].
TURNER, R .