SEGMENTATION OF BRAIN CT IMAGES USING THE CONCEPT OF REGION GROWING

被引:24
作者
SANDOR, T
METCALF, D
KIM, YJ
机构
[1] Department of Radiology, Harvard Medical School, Brigham and Women's Hospital, Boston
来源
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING | 1991年 / 29卷 / 02期
关键词
FEATURE EXTRACTION; DIGITAL RADIOLOGY; BRAIN SCANS; IMAGE SEGMENTATION; REGION GROWING;
D O I
10.1016/0020-7101(91)90004-X
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A method is described for extracting and isolating cerebrospinal fluid and tissue areas of brain images obtained with computed tomography. The classification of the pixels into components is based on region growing and nearest neighbor principles. To aid the performance of this method, the algorithm utilizes a priori information on the anatomic composition of the brain, and reduces the 'cupping effect' in the CT image that is attributed to beam hardening artifacts. In order to avoid subjectivity, the performance of the algorithm was tested by superimposing five computer-simulated circular lesions on different areas of the original CT scans, 8 mm thick. These images were taken at different levels in the brain, thereby accommodating different anatomy as well as the apical artifact of CT scanning. In this exploratory investigation, the false negative error of segmentation for lesions having diameter of 20 pixels was found in the order of 25% at an estimated partial volume (PV) effect of 50% that decrease further to about 5% for a PV of 80%. At that point the false positive error becomes the dominant error in the analysis.
引用
收藏
页码:133 / 147
页数:15
相关论文
共 25 条
[11]  
JOSEPH PM, 1981, RADIOLOGY SKULL BRAI, V5
[12]   EVALUATION OF A PROTOTYPE DUAL-ENERGY COMPUTED TOMOGRAPHIC APPARATUS .1. PHANTOM STUDIES [J].
KALENDER, WA ;
PERMAN, WH ;
VETTER, JR ;
KLOTZ, E .
MEDICAL PHYSICS, 1986, 13 (03) :334-339
[13]   A SEGMENTATION SYSTEM BASED ON THRESHOLDING [J].
KOHLER, R .
COMPUTER GRAPHICS AND IMAGE PROCESSING, 1981, 15 (04) :319-338
[14]   THE REMOVAL OF A CUPPING ARTIFACT FROM BRAIN IMAGES PRODUCED BY THE EMI-7070 CT SCANNER [J].
MOTT, DJ ;
ZHENG, GL ;
EDDLESTON, B .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (693) :873-880
[15]  
Pavlidis T., 1977, STRUCTURAL PATTERN R
[16]   COMPUTER-INTERACTIVE METHOD FOR QUANTIFYING CEREBROSPINAL-FLUID AND TISSUE IN BRAIN CT SCANS - EFFECTS OF AGING [J].
PFEFFERBAUM, A ;
ZATZ, LM ;
JERNIGAN, TL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (04) :571-578
[17]  
Pratt W. K., 1978, DIGITAL IMAGE PROCES
[18]  
Reiber J H, 1984, IEEE Trans Med Imaging, V3, P131, DOI 10.1109/TMI.1984.4307669
[19]  
REIBER JHC, 1975, THESIS STANFORD U
[20]  
ROSENFELD A, 1983, FUNDAMENTALS COMPUTE, P225