SIMULTANEOUS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ADENOSINE AND DOPAMINE IN RAT STRIATAL TISSUE WITH COMBINED ULTRAVIOLET ABSORBENCY AND ELECTROCHEMICAL DETECTION

被引:10
|
作者
BETTO, P [1 ]
POPOLI, P [1 ]
RICCIARELLO, G [1 ]
CAPORALI, MG [1 ]
ANTONINI, R [1 ]
机构
[1] IST SUPER SANITA,FARMACOL LAB,I-00161 ROME,ITALY
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1994年 / 662卷 / 01期
关键词
D O I
10.1016/0378-4347(94)00385-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is described for the simultaneous determination of biogenic amines, adenosine and their metabolites in rat striatal tissue using high-performance liquid chromatography with ultraviolet spectrophotometric and electrochemical detection. Peaks in the chromatograms of striatal tissue extracts were identified by retention times and by on-line analysis of peak spectra for adenosine and its metabolites, and by comparing current ratios of the dual-electrode coulometric detector for monoamines and metabolites. The assay gives a linear response over the concentration range of 0.15-0.60 mu g/ml for biogenic amines, 0.5-2.0 mu g/ml for serotonin, 5-20 mu g/ml for hypoxanthine, adenosine and N-methyladenosine, and 10-40 mu g/ml for inosine. The limit of detection for striatal homogenates was 3.5 ng/g for monoamines, 9 ng/g for serotonine, 140 ng/g for hypoxanthine, 290 ng/g for inosine and 80 ng/g for adenosine. The recovery ranged from 88.5% for vanillylmandelic acid to 110.3% for dopamine. The method was used to measure biogenic amines, adenosine and related metabolites in rat striatal tissues.