IS DISTAL SAMPLING OF END-TIDAL CO2 NECESSARY IN SMALL SUBJECTS

被引:26
作者
RICH, GF [1 ]
SULLIVAN, MP [1 ]
ADAMS, JM [1 ]
机构
[1] UNIV VIRGINIA, DEPT BIOMED ENGN, CHARLOTTESVILLE, VA 22908 USA
关键词
carbon dioxide: end-tidal CO[!sub]2[!/sub; measurement techniques: capnometry;
D O I
10.1097/00000542-199008000-00013
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The authors compared Pa(CO2) with end-tidal CO2 (ET(CO2)) sampled at multiple sites along the endotracheal tube (ETT) in seven anesthetized rabbits (weight, 2.7-3.6 kg) to determine the most convenient, yet accurate, sampling location. Comparisons were made during spontaneous and controlled ventilation with fresh gas flows (FGF) of two and ten times the minute ventilation using a Mapleson D circuit. An Engstrom Eliza analyzer with a continuous sampling rate of 100 ml/min was used to measure ET(CO2). A 0.75-mm ID polyethylene tube inserted in the side of the ETT sampled ET(CO2) at the distal tip and at the 6-, 12-, and 15-cm marks on the ETT. ET(CO2) was also measured at the standard proximal connector. The differences (P < 0.05) between Pa(CO2) and ET(CO2) at the distal, 6-, 12-, and 15-cm marks were 2.9 ± 0.4, 3.1 ± 0.4, 3.6 ± 0.4, and 4.6 ± 0.5 mmHg (x̄ ± SEM), respectively, and did not change with FGF or mode of ventilation. The difference between Pa(CO2) and ET(CO2) measured at the proximal connector was always large but significantly (P < 0.05) greater during spontaneous than controlled ventilation (24.2 ± 1.5 versus 15.0 ± 1.4 mmHg) and at higher FGF (19.4 ± 1.3 versus 16.8 ± 1.6 mmHg). The differences (P < 0.05) between ET(CO2) at the distal tip and ET(CO2) at the 6-, 12-, and 15-cm marks were 0.24 ± 0.07, 0.73 ± 0.11, and, 1.77 ± 0.20 mmHg, respectively. This demonstrates that the change in ET(CO2) between the distal tip and the 12-cm mark on the ETT is less than 1 mmHg, and that this clinically insignificant difference is independent of FGF and mode of ventilation. The 12-cm mark is outside of the mouth on a newborn, and sampling ET(CO2) at that point, which may be accomplished simply by inserting a small needle in the side of the ETT, may be the most appropriate sampling location.
引用
收藏
页码:265 / 268
页数:4
相关论文
共 15 条
[1]  
BADGWELL JM, 1987, ANESTH ANALG, V66, P959
[2]   END-TIDAL P-CO2 MONITORING IN INFANTS AND CHILDREN VENTILATED WITH EITHER A PARTIAL REBREATHING OR A NON-REBREATHING CIRCUIT [J].
BADGWELL, JM ;
HEAVNER, JE ;
MAY, WS ;
GOLDTHORN, JF ;
LERMAN, J .
ANESTHESIOLOGY, 1987, 66 (03) :405-410
[3]   END-TIDAL CO-2 MONITORING - ITS USE IN THE DIAGNOSIS AND MANAGEMENT OF MALIGNANT HYPERTHERMIA [J].
BAUDENDISTEL, L ;
GOUDSOUZIAN, N ;
COTE, C ;
STRAFFORD, M .
ANAESTHESIA, 1984, 39 (10) :1000-1003
[4]  
BIRMINGHAM PK, 1986, ANESTH ANALG, V65, P886
[5]   SINGLE BREATH END-TIDAL CO2 ESTIMATES OF ARTERIAL PCO2 IN INFANTS AND CHILDREN [J].
BISSONNETTE, B ;
LERMAN, J .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1989, 36 (02) :110-112
[6]  
EICHHORN JH, 1986, JAMA-J AM MED ASSOC, V256, P1017
[7]  
Gravenstein N, 1985, J Clin Monit, V1, P6, DOI 10.1007/BF02832683
[8]   CAPNOGRAPHY FOR DETECTION OF ACCIDENTAL ESOPHAGEAL INTUBATION [J].
LINKO, K ;
PALOHEIMO, M ;
TAMMISTO, T .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1983, 27 (03) :199-202
[9]  
MOGUE LR, 1988, J CLIN MONITOR, V4, P115
[10]   EARLY DETECTION OF ENDOTRACHEAL-TUBE ACCIDENTS BY MONITORING CARBON-DIOXIDE CONCENTRATION IN RESPIRATORY GAS [J].
MURRAY, IP ;
MODELL, JH .
ANESTHESIOLOGY, 1983, 59 (04) :344-346