FACTORS AFFECTING ADHESION ON CONCRETE OF ARC-SPRAYED ZINC

被引:4
作者
BROUSSEAU, R [1 ]
ARNOTT, M [1 ]
DALLAIRE, S [1 ]
FELDMAN, R [1 ]
机构
[1] NATL RES COUNCIL CANADA,BOUCHERVILLE,QUEBEC,CANADA
关键词
CATHODIC PROTECTION; CONCRETE; METALLIZED; REINFORCEMENT; ZINC;
D O I
10.5006/1.3315898
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Arc-sprayed zinc coatings are more frequently used as anode for the cathodic protection of reinforced concrete structures. However, as with any other conductive coating, zinc should be applied with the highest possible adhesion in order to serve as a durable anode. Factors affecting the adhesion of zinc on concrete are discussed here for the first time. Preheating the concrete surface prior to zinc application has been found to be particularly beneficial. The measured adhesion values have also been found to vary significantly with the pull out procedure.
引用
收藏
页码:947 / 952
页数:6
相关论文
共 13 条
  • [1] APOSTOLOS JA, 1983, CORROSION 83 PAP
  • [2] APOSTOLOS JA, 1984, TRB962 NAT RES COUNC, P22
  • [3] CARELLO RA, 1989, FHWACATL8904 REP
  • [4] CHANG GC, 1981, FHWACATL8102 CAL DEP
  • [5] ELLIS WJ, 1980, NCHRP1219 PROJ
  • [6] ELLIS WJ, 1979, NCHRP1219 PROJ
  • [7] FROMM HJ, 1976, CATHODIC PROTECTION, P38
  • [8] MANNING DG, 1985, TRB1041 TRANSP RES R, P23
  • [9] NICHOLSON JP, 1980, 762 TRANSP RES REC, P13
  • [10] SAGUES AA, 3RD Q REP