Integrated approach for school buildings rehabilitation in a Portuguese city and analysis of suitable third party financing solutions in EU

被引:20
作者
Bras, Ana [1 ]
Rocha, Ana [1 ]
Faustino, Pedro [2 ]
机构
[1] ESTB Polytech Inst Setubal, Construct & Environm Sect, Setubal, Portugal
[2] LEB Designers & Cosultants Rehabil Construct, Alcabideche, Portugal
关键词
Integrated approach for school building rehabilitation; Energy consumption for heating and cooling; Payback; Thermal rehabilitation; LCC; Available financial mechanisms to promote; buildings energy efficiency measures;
D O I
10.1016/j.jobe.2015.05.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper we present an integrated approach for building rehabilitation on a group of buildings of a primary school located in the southern suburbs of Lisbon - Moita, Portugal. The approach includes taking into account collected data concerning the actual energy consumption for: space heating; occupants' behavior, technical and architectural characteristics of the buildings. Detailed energy auditing was done to the buildings including interviews to pupils and teachers to understand occupants behavior, construction materials used, energy consumption and lighting. Thermal images of the interior zones were generated to provide information about the temperature distribution and a notion about air or heat leak from or into the building. Based on the obtained data, 5 different energy retrofit scenarios were studied with different performance and cost-effectiveness targets. compatible with some European available financial mechanisms to promote energy retrofit of buildings. Life cycle cost analyses (LCC) should be taken into account to minimize environmental impact and some recommendations were suggested. Each scenario service life' presents an important effect in LCC It s found that implementing those measures can cost-effectively reduce the annual energy use by 40% compared to the original building design. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:79 / 93
页数:15
相关论文
共 28 条
[1]   Energy audit of an educational building in a hot summer climate [J].
Alajmi, Ali .
ENERGY AND BUILDINGS, 2012, 47 :122-130
[2]  
[Anonymous], REN EN STRAT
[3]  
[Anonymous], 2012, ENERGY CITIES REPORT
[4]  
[Anonymous], 2012, OFFICIAL J EUROPEAN, VL315
[5]  
[Anonymous], 2008, 13790 EN ISO
[6]  
[Anonymous], 2016, STRAT EN EFF
[7]   Energy retrofit of an educational building in the ancient center of Benevento. Feasibility study of energy savings and respect of the historical value [J].
Ascione, Fabrizio ;
Bianco, Nicola ;
De Masi, Rosa Francesca ;
de'Rossi, Filippo ;
Vanoli, Giuseppe Peter .
ENERGY AND BUILDINGS, 2015, 95 :172-183
[8]   Decision making under uncertainty in the retrofit analysis of the UK housing stock: Implications for the Green Deal [J].
Booth, A. T. ;
Choudhary, R. .
ENERGY AND BUILDINGS, 2013, 64 :292-308
[9]   LCA implementation in the selection of thermal enhanced mortars for energetic rehabilitation of school buildings [J].
Bras, Ana ;
Gomes, Vanessa .
ENERGY AND BUILDINGS, 2015, 92 :1-9
[10]   Cork-based mortars for thermal bridges correction in a dwelling: Thermal performance and cost evaluation [J].
Bras, Ana ;
Goncalves, Fabio ;
Faustino, Pedro .
ENERGY AND BUILDINGS, 2014, 72 :296-308