PERFORMANCE OF THE CHARGE-COUPLED DEVICE FOR DIRECT X-RAY-DETECTION IN THE ENERGY-RANGE OF 1-9 KEV AT THE SYNCHROTRON RADIATION FACILITY

被引:18
作者
TSUNEMI, H
KAWAI, S
HAYASHIDA, K
机构
[1] Department of Physics, Osaka University, Toyonaka Osaka, 560
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1991年 / 30卷 / 06期
关键词
CHARGE-COUPLED DEVICE; X-RAY IMAGER; X-RAY SPECTROMETER; SYNCHROTRON RADIATION;
D O I
10.1143/JJAP.30.1299
中图分类号
O59 [应用物理学];
学科分类号
摘要
We performed a calibration of the charge-coupled device (CCD) in the direct X-ray detection method. The CCD chip is a product for optical use. The X-rays which we used are from the BL-7A in the Ultraviolet Synchrotron Orbit Radiation (UVSOR) facility, which gives us X-rays in the energy range between 1 and 9 keV. We report here the various characteristics of the CCD and its validity as an X-ray imager with a spatial resolution of pixel size (12 x 12-mu-m2) as well as an X-ray spectrometer at an energy resolution of about 240 eV (full width at half-maximum; FWHM) at the 5.9 keV X-ray. Our system functioned properly at a standard flux level in the UVSOR facility.
引用
收藏
页码:1299 / 1302
页数:4
相关论文
共 9 条
[1]   DESIGN AND PERFORMANCE OF AN IMAGING PLATE SYSTEM FOR X-RAY-DIFFRACTION STUDY [J].
AMEMIYA, Y ;
MATSUSHITA, T ;
NAKAGAWA, A ;
SATOW, Y ;
MIYAHARA, J ;
CHIKAWA, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :645-653
[2]   DESIGN OF LOW-NOISE, HIGH-PERFORMANCE X-RAY CHARGE-COUPLED-DEVICE CAMERAS [J].
DOTY, JP ;
LUPPINO, GA ;
RICKER, GR .
OPTICAL ENGINEERING, 1987, 26 (10) :1055-1060
[3]   APPLICATIONS OF CHARGE-COUPLED-DEVICES TO X-RAY ASTROPHYSICS MISSIONS [J].
LUMB, DH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01) :219-226
[4]   SOFT-X-RAY DAMAGE IN CCD DETECTORS [J].
MAGORRIAN, BG ;
ALLINSON, NM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3) :599-604
[5]   MICROCOMPUTER-ASSISTED CCD DRIVER SYSTEM FOR GENERAL USE [J].
MIZUKATA, K ;
TSUNEMI, H .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1988, 27 (10) :2015-2016
[6]  
MORITA S, 1987, NUCL FUSION, V58, P485
[7]   THE MPI AIT X-RAY IMAGER (MAXI) - HIGH-SPEED PN CCDS FOR X-RAY-DETECTION [J].
STRUDER, L ;
BRAUNINGER, H ;
MEIER, M ;
PREDEHL, P ;
REPPIN, C ;
STERZIK, M ;
TRUMPER, J ;
CATTANEO, P ;
HAUFF, D ;
LUTZ, G ;
SCHUSTER, KF ;
SCHWARZ, A ;
KENZIORRA, E ;
STAUBERT, A ;
GATTI, E ;
LONGONI, A ;
SAMPIETRO, M ;
RADEKA, V ;
REHAK, P ;
RESCIA, S ;
MANFREDI, PF ;
BUTTLER, W ;
HOLL, P ;
KEMMER, J ;
PRECHTEL, U ;
ZIEMANN, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01) :227-235
[8]   APPLICATION OF A FRAME TRANSFER-TYPE CCD AS AN X-RAY IMAGE SENSOR [J].
TSUNEMI, H ;
MIZUKATA, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1988, 27 (12) :2404-2408
[9]  
Tsunemi H., 1990, Review of Laser Engineering, V18, P923, DOI 10.2184/lsj.18.11_923