Comparative dosimetry of GammaMed Plus high-dose rate Ir-192 brachytherapy source

被引:6
作者
Patel, N. P. [1 ,2 ]
Majumdar, B. [1 ]
Vijayan, V. [3 ]
机构
[1] Govt Coll Sci, Dept Phys, Raipur, Madhya Pradesh, India
[2] AH Reg Canc Ctr, Dept Med Phys, Cuttack, Orissa, India
[3] Inst Phys, Bhubaneswar, Orissa, India
关键词
0.1-cc chamber; AAPM TG-43; dosimetry; EGSnrc simulation code; high dose rate;
D O I
10.4103/0971-6203.66761
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The comparative dosimetry of GammaMed (GM) Plus high-dose rate brachytherapy source was performed by an experiment using 0.1-cc thimble ionization chamber and simulation-based study using EGSnrc code. In-water dose measurements were performed with 0.1-cc chamber to derive the radial dose function (r = 0.8 to 20.0 cm) and anisotropy function (r = 5.0 cm with polar angle from 10 degrees to 170 degrees). The nonuniformity correction factor for 0.1-cc chamber was applied for in-water measurements at shorter distances from the source. The EGSnrc code was used to derive the dose rate constant (L), radial dose function g L (r) and anisotropy function F(r, q) of GM Plus source. The dosimetric data derived using EGSnrc code in our study were in very good agreement relative to published data for GM Plus source. The radial dose function up to 12 cm derived from measured dose using 0.1-cc chamber was in agreement within 3% of data derived by the simulation study.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 31 条
  • [1] [Anonymous], 2002, 1274 IAEATECDOC
  • [2] Technical note:: Monte-Carlo dosimetry of the HDR 12i and plus 192Ir sources
    Ballester, F
    Puchades, V
    Lluch, JL
    Serrano-Andrés, MA
    Limami, Y
    Pérez-Calatayud, J
    Casal, E
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2586 - 2591
  • [3] Borg J, MONTE CARLO CALCULAT
  • [4] Determination of the tissue attenuation factor along two major axes of a high dose rate (HDR) 192Ir source
    Cho, SH
    Muller-Runkel, R
    Hanson, WF
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1492 - 1497
  • [5] Duchemin B, 1993, 93018 LPRI DAMRICEA
  • [6] HUBBELL JH, TABLES X RAY MASS AT
  • [7] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [8] Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations
    Kawrakow, I
    [J]. MEDICAL PHYSICS, 2000, 27 (03) : 499 - 513
  • [9] Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    Kawrakow, I
    [J]. MEDICAL PHYSICS, 2000, 27 (03) : 485 - 498
  • [10] Kawrakow I, 2003, 877 PIRS NAT RES COU