Recent advances in noninvasive glucose monitoring

被引:174
作者
So, Chi-Fuk [1 ]
Choi, Kup-Sze [1 ]
Wong, Thomas K. S. [2 ]
Chung, Joanne W. Y. [2 ,3 ]
机构
[1] Hong Kong Polytech Univ, Ctr Integrat Digital Hlth, Sch Nursing, Kowloon, Hong Kong, Peoples R China
[2] Tung Wah Coll, Dept Nursing & Hlth Sci, Kowloon, Hong Kong, Peoples R China
[3] Hong Kong Inst Educ, Dept Hlth & Phys Educ, Kowloon, Hong Kong, Peoples R China
关键词
noninvasive; glucose monitoring; diabetes mellitus; blood glucose measurement;
D O I
10.2147/MDER.S28134
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The race for the next generation of painless and reliable glucose monitoring for diabetes mellitus is on. As technology advances, both diagnostic techniques and equipment improve. This review describes the main technologies currently being explored for noninvasive glucose monitoring. The principle of each technology is mentioned; its advantages and limitations are then discussed. The general description and the corresponding results for each device are illustrated, as well as the current status of the device and the manufacturer; internet references for the devices are listed where appropriate. Ten technologies and eleven potential devices are included in this review. Near infrared spectroscopy has become a promising technology, among others, for blood glucose monitoring. Although some reviews have been published already, the rapid development of technologies and information makes constant updating mandatory. While advances have been made, the reliability and the calibration of noninvasive instruments could still be improved, and more studies carried out under different physiological conditions of metabolism, bodily fluid circulation, and blood components are needed.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 39 条
[1]  
[Anonymous], 2012, DIABETES CARE, V35, pS11, DOI [10.2337/dc12-s011, 10.2337/dc35-S011, 10.2337/dc12-s004]
[2]  
[Anonymous], 2010, BIOSCIENCES
[3]  
[Anonymous], 2001, NEAR INFRARED APPL B
[4]   Noninvasive glucose sensing [J].
Arnold, MA ;
Small, GW .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5429-5439
[5]   Multicomponent blood analysis by near-infrared Raman spectroscopy [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Horowitz, G ;
Feld, MS .
APPLIED OPTICS, 1999, 38 (13) :2916-2926
[6]   Attenuated total reflection-fourier transform infrared spectroscopy as a possible method to investigate biophysical parameters of stratum corneum in vivo [J].
Brancaleon, L ;
Bamberg, MP ;
Sakamaki, T ;
Kollias, N .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2001, 116 (03) :380-386
[7]   First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system [J].
Caduff, A ;
Hirt, E ;
Feldman, Y ;
Ali, Z ;
Heinemann, L .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) :209-217
[8]   Non-invasive glucose monitoring in patients with Type 1 diabetes: A Multisensor system combining sensors for dielectric and optical characterisation of skin [J].
Caduff, Andreas ;
Talary, Mark S. ;
Mueller, Martin ;
Dewarrat, Francois ;
Klisic, Jelena ;
Donath, Marc ;
Heinemann, Lutz ;
Stahel, Werner A. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (09) :2778-2784
[9]   In Vivo Blood Characterization From Bioimpedance Spectroscopy of Blood Pooling [J].
Dai, Tao ;
Adler, Andy .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (11) :3831-3838
[10]  
Diabetesnet.com, 2010, FUT MET MON