AN LH2 TARGET ARRANGEMENT FOR LOW CROSS-SECTION MEASUREMENTS

被引:2
|
作者
EDWARDS, GWR [1 ]
COOMBES, GH [1 ]
KELLNER, W [1 ]
HUTCHEON, DA [1 ]
MILLER, CA [1 ]
ABEGG, R [1 ]
GREENIAUS, LG [1 ]
机构
[1] UNIV BRITISH COLUMBIA,TRIUMF,VANCOUVER V6T 2A3,BC,CANADA
关键词
D O I
10.1016/0168-9002(92)90848-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A liquid hydrogen target has been constructed for use in the measurement of low cross section reactions with a single detected charged particle in the final state, for example p(n, d)gamma, n(p, d)pi-0 or p(p, d)pi+. It uses thin plastic scintillation counters mounted close to the target container, in contact with a cold gas cell between the liquid hydrogen and an insulation vacuum. Pulse height information from these counters allows background events originating in most of the windows of the target assembly to be eliminated. The design and operational characteristics of the target are described.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [1] A Reference Target for Polarimetric Radar Cross-Section Measurements
    Dallmann, Thomas
    Heberling, Dirk
    2014 8TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2014, : 2313 - +
  • [2] TARGET THICKNESS EFFECTS IN SINGLE COLLISION CROSS-SECTION MEASUREMENTS
    HIRD, B
    SUK, HC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (05): : 818 - 818
  • [3] THE INFLUENCE OF TARGET IMPURITIES ON THE ACCURACY OF REACTION CROSS-SECTION MEASUREMENTS
    CHENG, XW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 282 (01): : 312 - 314
  • [4] TOTAL CROSS-SECTION MEASUREMENTS WITH POLARIZED BEAM AND POLARIZED TARGET
    JOHNSEN, SW
    BRADY, FP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (01): : 152 - &
  • [5] Ultracold atoms as a target: absolute scattering cross-section measurements
    Wuertz, P.
    Gericke, T.
    Vogler, A.
    Ott, H.
    NEW JOURNAL OF PHYSICS, 2010, 12
  • [6] Active calibration target for bistatic radar cross-section measurements
    Pienaar, M.
    Odendaal, J. W.
    Joubert, J.
    Cilliers, J. E.
    Smit, J. C.
    RADIO SCIENCE, 2016, 51 (05) : 515 - 523
  • [7] FUSION CROSS-SECTION MEASUREMENTS WITH DEUTERONS OF LOW ENERGY
    VONENGEL, A
    GOODYEAR, CC
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1961, 264 (1318) : 445 - +
  • [8] The Qweak high performance LH2 target
    Brock, J.
    Dusa, S. Covrig
    Dunne, J. A.
    Keith, C.
    Meekins, D.
    Pierce, J.
    Smith, G. R.
    Subedi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1053
  • [9] RADAR CROSS-SECTION MEASUREMENTS
    DYBDAL, RB
    PROCEEDINGS OF THE IEEE, 1987, 75 (04) : 498 - 516
  • [10] TARGET SPINOR CALIBRATION (TSC) FOR POLARIMETRIC RADAR CROSS-SECTION MEASUREMENTS
    FABREGAS, X
    ROMEU, J
    BROQUETAS, A
    JOFRE, L
    ELECTRONICS LETTERS, 1995, 31 (19) : 1694 - 1695