NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE

被引:338
作者
IMHOLZ, BPM
SETTELS, JJ
VANDERMEIRACKER, AH
WESSELING, KH
WIELING, W
机构
[1] TNO, BIOMED INSTRUMENTAT, THE HAGUE, NETHERLANDS
[2] ERASMUS UNIV, HOSP DIJKZIGT, DEPT INTERNAL MED 1, ROTTERDAM, NETHERLANDS
关键词
Continuous finger blood pressure; Intra-arterial blood pressure; Orthostatic stress;
D O I
10.1093/cvr/24.3.214
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Study objective - The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses.Design - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during active standing from the supine or sitting position in healthy volunteers.Subjects - Subjects (n=ll) were healthy males aged 22-40 years, mean age 30 years.Measurements and main results - Beat to beat values of systolic, diastolic, and mean arterial pressures were calculated for both methods of measurement and the differences compared during a 30 s control period before, and during the first 120 s after, the change of posture. In the control period the difference between finger pressure and intra-arterial pressure was +2 (SD11) mm Hg for systolic, -4(8) mm Hg for mean, and -3(7) mm Hg for diastolic pressure. Compared to these control differences, the average finger minus intra-arterial pressure differences for mean and diastolic pressures during the three orthostatic manoeuvres were always within the range -6 to +6 mm Hg. The average systolic deviations were larger, ranging from -10 to +11 mm Hg. Despite these differences the characteristic changes in intra-arterial pressure during the initial phase (first 30 s after change of posture), as well as during the early steady state phase (1-2 min after the change of posture) were well reflected by finger pressure measurements in all subjecs.Conclusions - For the assessment of the continuous blood pressure responses to orthostatic stress similar information can be obtained with non-invasive Finapres blood pressure recordings as with invasive recordings.
引用
收藏
页码:214 / 221
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 1956, NONPARAMETRIC STAT B
[2]   THE EFFECT OF BODY POSTURE ON THE HAND BLOOD FLOW [J].
BEACONSFIELD, P ;
GINSBURG, J .
JOURNAL OF PHYSIOLOGY-LONDON, 1955, 130 (02) :467-473
[3]  
BLOMQVIST CG, 1983, HDB PHYSL CARDIOVA 2, V3, P497
[4]   MECHANISMS OF INITIAL HEART-RATE RESPONSE TO POSTURAL CHANGE [J].
BORST, C ;
WIELING, W ;
VANBREDERODE, JFM ;
HOND, A ;
DERIJK, LG ;
DUNNING, AJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 243 (05) :H676-H681
[5]   EFFECTS OF PERIPHERAL VASOCONSTRICTION ON THE BLOOD-PRESSURE IN THE FINGER, MEASURED CONTINUOUSLY BY A NEW NONINVASIVE METHOD (THE FINAPRES) [J].
DORLAS, JC ;
NIJBOER, JA ;
BUTIJN, WT ;
VANDERHOEVEN, GMA ;
SETTELS, JJ ;
WESSELING, KH .
ANESTHESIOLOGY, 1985, 62 (03) :342-345
[6]   AUTONOMIC MECHANISMS IN THE INITIAL HEART-RATE RESPONSE TO STANDING [J].
EWING, DJ ;
HUME, L ;
CAMPBELL, IW ;
MURRAY, A ;
NEILSON, JMM ;
CLARKE, BF .
JOURNAL OF APPLIED PHYSIOLOGY, 1980, 49 (05) :809-814
[7]   DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[8]  
GOEDHARD WJA, 1983, PSYCHOPHYSIOLOGY CAR, P191
[9]   CONTINUOUS NON-INVASIVE BLOOD-PRESSURE MONITORING - RELIABILITY OF FINAPRES DEVICE DURING THE VALSALVA MANEUVER [J].
IMHOLZ, BPM ;
VANMONTFRANS, GA ;
SETTELS, JJ ;
VANDERHOEVEN, GMA ;
KAREMAKER, JM ;
WIELING, W .
CARDIOVASCULAR RESEARCH, 1988, 22 (06) :390-397
[10]  
Kurki T, 1987, J Clin Monit, V3, P6, DOI 10.1007/BF00770876