Hemodynamic Effects of Noninvasive Positive-Pressure Ventilation Assessed Using Transthoracic Echocardiography

被引:6
作者
Au, Shek Yin [1 ,2 ]
Lau, Cheuk Ling [1 ,2 ]
Chen, Ka King [1 ,2 ]
Cheong, Adrian Piers [1 ,2 ]
Tong, Ying Ting [3 ]
Chan, Lip Kiong [1 ,2 ]
机构
[1] Open Univ Hong Kong, Alice Ho Miu Ling Nethersole Hosp, Dept Med, Hong Kong, Hong Kong, Peoples R China
[2] Open Univ Hong Kong, Alice Ho Miu Ling Nethersole Hosp, Intens Care Unit, Hong Kong, Hong Kong, Peoples R China
[3] Open Univ Hong Kong, Sch Sci & Technol, Div Nursing & Hlth Studies, Hong Kong, Hong Kong, Peoples R China
关键词
Continuous positive-pressure ventilation; echocardiography; hemodynamic;
D O I
10.4103/jcecho.jcecho_53_17
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The aim of this study is to measure the effect of positive-pressure ventilation on heart chamber dimensions, left ventricular (LV) systolic function, LV diastolic function, right ventricular (RV) systolic function, and RV pressure using transthoracic echocardiography. Settings and Design: This is a prospective study in a single secondary health-care center. Materials and Methods: A total of 107 patients with obstructive sleep apnea on continuous positive airway pressure (CPAP) therapy were recruited as participants between April and September 2016. Transthoracic echocardiography was performed twice on each participant, before and 15 min after, they used their own CPAP machines, and the echocardiography parameters of both scans were compared. Statistical Analysis Used: The parametric paired t-test was used to compare heart chamber dimensions, left heart diastolic function, left heart systolic function, right heart systolic function, and right heart pressure effect, without and with CPAP. These data were further examined among several subgroups defined by CPAP when the cutoff point was set at 8 cmH(2)O and 10 cmH(2)O. The level of significance was set at 0.05. Statistical analyses were performed using IBM SPSS version 22 (IBM, Armonk, NY, USA). Results: There were statistically significant reductions, after the application of CPAP, in the heart dimensions, and LV and RV systolic function. There were no significant changes in diastolic function. Concerning right heart pressure, with CPAP, there was a significant increase in the inferior vena cava (IVC) diameter and there was also a significant decrease in IVC variability from 44.56% +/- 14.86% to 36.12% +/- 11.42%. The maximum velocity of tricuspid regurgitation (TR) decreased significantly from 180.66 +/- 6.95 cm/s to 142.30 +/- 52.73 cm/s. Such changes were observed in both low and high CPAP subgroups. Conclusions: When placed on positive pressure, the clinically significant change in IVC diameter and variability and change in trans-TR velocity mean that it would be inaccurate to predict right heart chamber pressure through echocardiogram. Alternative methods for predicting right heart pressure are recommended.
引用
收藏
页码:114 / 119
页数:6
相关论文
共 24 条
[1]   HEMODYNAMIC-EFFECTS OF PRESSURE SUPPORT AND PEEP VENTILATION BY NASAL ROUTE IN PATIENTS WITH STABLE CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
AMBROSINO, N ;
NAVA, S ;
TORBICKI, A ;
RICCARDI, G ;
FRACCHIA, C ;
OPASICH, C ;
RAMPULLA, C .
THORAX, 1993, 48 (05) :523-528
[2]  
Cao Feng, 2008, Zhongguo Wei Zhong Bing Ji Jiu Yi Xue, V20, P341
[3]  
Dambrosio M, 1996, INTENS CARE MED, V22, P772, DOI 10.1007/s001340050166
[4]   Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome [J].
Gernoth, Christian ;
Wagner, Gerhard ;
Pelosi, Paolo ;
Luecke, Thomas .
CRITICAL CARE, 2009, 13 (02)
[5]  
Gomersall C., ICU WEB CRITICAL CAR
[6]   EFFECTS OF POSITIVE END-EXPIRATORY PRESSURE ON THE RIGHT VENTRICLE [J].
HENNING, RJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (03) :819-826
[7]   INFLUENCE OF POSITIVE END-EXPIRATORY PRESSURE ON RIGHT AND LEFT-VENTRICULAR PERFORMANCE ASSESSED BY DOPPLER 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
HUEMER, G ;
KOLEV, N ;
KURZ, A ;
ZIMPFER, M .
CHEST, 1994, 106 (01) :67-73
[8]   Hemodynamic effects of Intermittent manual lung hyperinflation in patients with septic shock [J].
Jellema, WT ;
Groeneveld, J ;
van Goudoever, J ;
Wesseling, KH ;
Westerhof, N ;
Lubbers, MJ ;
Kesecioglu, J ;
van Lieshout, JJ .
HEART & LUNG, 2000, 29 (05) :356-366
[9]   Acute and chronic effects of continuous positive airway pressure therapy on left ventricular systolic and diastolic function in patients with obstructive sleep apnea and congestive heart failure [J].
Johnson, Chris B. ;
Beanlands, Rob S. ;
Yoshinaga, Keiichiro ;
Haddad, Haissam ;
Leech, Judith ;
de Kemp, Rob ;
Burwash, Ian G. .
CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (09) :697-704
[10]   Haemodynamic changes during positive-pressure ventilation in children [J].
Kardos, A ;
Vereczkey, G ;
Szentirmai, C .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (05) :649-653