OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA

被引:1232
作者
HEE, MR
IZATT, JA
SWANSON, EA
HUANG, D
SCHUMAN, JS
LIN, CP
PULIAFITO, CA
FUJIMOTO, JG
机构
[1] MIT,DEPT ELECT ENGN & COMP SCI,ELECTR RES LAB,CAMBRIDGE,MA 02139
[2] HARVARD UNIV,SCH MED,BOSTON,MA
[3] MIT,LINCOLN LAB,LEXINGTON,MA 02173
[4] TUFTS UNIV,SCH MED,NEW ENGLAND EYE CTR,BOSTON,MA 02111
关键词
D O I
10.1001/archopht.1995.01100030081025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To demonstrate optical coherence tomography for high-resolution, noninvasive imaging of the human retina. Optical coherence tomography is a new imaging technique analogous to ultrasound B scan that can provide cross-sectional images of the retina with micrometer-scale resolution. Design: Survey optical coherence tomographic examination of the retina, including the macula and optic nerve head in normal human subjects. Setting: Research laboratory. Participants: Convenience sample of normal human subjects. Main Outcome Measures: Correlation of optical coherence retinal tomographs with known normal retinal anatomy. Results: Optical coherence tomographs can discriminate the cross-sectional morphologic features of the fovea and optic disc, the layered structure of the retina, and normal anatomic variations in retinal and retinal nerve fiber layer thicknesses with 10-mu m depth resolution. Conclusion: Optical coherence tomography is a potentially useful technique for high depth resolution, cross-sectional examination of the fundus.
引用
收藏
页码:325 / 332
页数:8
相关论文
共 34 条
[1]  
BENNETT AG, 1962, EYE VISUAL OPTICS OP, P101
[2]  
BILLE JF, 1990, NONINVASIVE DIAGNOST, P528
[3]  
CHANDRA DRP, 1992, GROWTH AND WATER USE OF FOREST PLANTATIONS, P30
[4]   HIGH-RESOLUTION REFLECTOMETRY IN BIOLOGICAL TISSUES [J].
CLIVAZ, X ;
MARQUISWEIBLE, F ;
SALATHE, RP ;
NOVAK, RP ;
GILGEN, HH .
OPTICS LETTERS, 1992, 17 (01) :4-6
[5]  
FERCHER AF, 1988, OPT LETT, V13, P1867
[6]   FEMTOSECOND OPTICAL RANGING IN BIOLOGICAL-SYSTEMS [J].
FUJIMOTO, JG ;
DESILVESTRI, S ;
IPPEN, EP ;
PULIAFITO, CA ;
MARGOLIS, R ;
OSEROFF, A .
OPTICS LETTERS, 1986, 11 (03) :150-152
[7]   SUBMILLIMETER OPTICAL REFLECTOMETRY [J].
GILGEN, HH ;
NOVAK, RP ;
SALATHE, RP ;
HODEL, W ;
BEAUD, P .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1989, 7 (08) :1225-1233
[8]   POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING [J].
HEE, MR ;
HUANG, D ;
SWANSON, EA ;
FUJIMOTO, JG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) :903-908
[9]  
HITZENBERGER CK, 1992, INVEST OPHTH VIS SCI, V33, P98
[10]   MICRON-RESOLUTION RANGING OF CORNEA ANTERIOR-CHAMBER BY OPTICAL REFLECTOMETRY [J].
HUANG, D ;
WANG, JP ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
LASERS IN SURGERY AND MEDICINE, 1991, 11 (05) :419-425