DETERMINATION OF CATECHOLAMINES IN URINE BY LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION AFTER ONLINE SAMPLE PURIFICATION ON IMMOBILIZED BORONIC ACID

被引:21
作者
ERIKSSON, BM
WIKSTROM, M
机构
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 593卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)80285-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Norepinephrine, epinephrine and dopamine in urine were measured by an automated liquid chromatographic method. After sample purification on a column containing silica-immobilized boronic acid, which showed great affinity for catecholamines at neutral pH, the catecholamines were eluted by backflushing with an acidic mobile phase and transferred to a cation exchanger for separation. Detection was performed electrochemically and the relative standard deviation was 2% for the analysis of endogenous concentrations in human urine.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 21 条
[1]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF URINARY CATECHOLAMINES AFTER ONE-STEP ALUMINA EXTRACTION [J].
ANDERSON, GM ;
DURKIN, TA ;
MORTON, JB ;
COHEN, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 424 (02) :373-377
[2]   ASSESSMENT OF SEMI-AUTOMATED CATECHOLAMINE ASSAY BY HPLC - CHOICE OF REVERSE PHASE C18 OR CATION-EXCHANGE COLUMNS [J].
BESCHI, M ;
CASTELLANO, M ;
AGABITIROSEI, E ;
RIZZONI, D ;
ROSSINI, P ;
MUIESAN, G .
CHROMATOGRAPHIA, 1987, 24 :455-459
[3]   DEVELOPMENT AND PERFORMANCE OF AN AUTOMATED HPLC-ANALYZER FOR CATECHOLAMINES [J].
BOOS, KS ;
WILMERS, B ;
SAUERBREY, R ;
SCHLIMME, E .
CHROMATOGRAPHIA, 1987, 24 :363-370
[4]   EVALUATION OF SAMPLE WORK-UP METHODS AND INTERNAL STANDARDS FOR THE DETERMINATION OF CATECHOLAMINES IN URINE BY HPLC WITH ELECTROCHEMICAL DETECTION [J].
CLAEYS, M ;
SCHEPERS, A ;
DILLEN, L ;
DEPOTTER, WP .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (6-8) :895-902
[5]   DETERMINATION OF CATECHOLAMINES IN URINE (AND PLASMA) BY LIQUID-CHROMATOGRAPHY AFTER ONLINE SAMPLE PRETREATMENT ON SMALL ALUMINA OR DIHYDROXYBORYLSILICA COLUMNS [J].
DEJONG, J ;
POINT, AJF ;
TJADEN, UR ;
BEEKSMA, S ;
KRAAK, JC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (02) :285-300
[6]  
Edlund P O, 1984, J Pharm Biomed Anal, V2, P315, DOI 10.1016/0731-7085(84)80082-5
[7]   DETERMINATION OF CATECHOLAMINES IN URINE BY ION-EXCHANGE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
ERIKSSON, BM ;
GUSTAFSSON, S ;
PERSSON, BA .
JOURNAL OF CHROMATOGRAPHY, 1983, 278 (02) :255-263
[8]   DETERMINATION OF VANILMANDELIC ACID IN URINE BY COUPLED-COLUMN LIQUID-CHROMATOGRAPHY COMBINING AFFINITY TO BORONATE AND SEPARATION BY ANION-EXCHANGE [J].
ERIKSSON, BM ;
WIKSTROM, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 567 (01) :1-9
[9]   MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SYSTEM WITH MICRO PRECOLUMN AND DUAL ELECTROCHEMICAL DETECTOR FOR DIRECT INJECTION-ANALYSIS OF CATECHOLAMINES IN BODY-FLUIDS [J].
GOTO, M ;
NAKAMURA, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (01) :33-42
[10]   A FULLY AUTOMATED CATECHOLAMINES ANALYZER BASED ON CARTRIDGE EXTRACTION AND HPLC SEPARATION [J].
GROSSI, G ;
BARGOSSI, A ;
LIPPI, A ;
BATTISTONI, R .
CHROMATOGRAPHIA, 1987, 24 :842-846