USE OF BIOELECTRICAL IMPEDANCE ANALYSIS TO MEASURE TOTAL-BODY WATER IN PATIENTS WITH CYSTIC-FIBROSIS

被引:33
|
作者
AZCUE, M
FRIED, M
PENCHARZ, PB
机构
[1] HOSP SICK CHILDREN, DIV CLIN NUTR, 555 UNIV AVE, TORONTO M5G 1X8, ONTARIO, CANADA
[2] UNIV TORONTO, DEPT PAEDIAT, TORONTO M5S 1A1, ONTARIO, CANADA
[3] UNIV TORONTO, DEPT NUTR SCI, TORONTO M5S 1A1, ONTARIO, CANADA
关键词
TOTAL BODY WATER; BODY COMPOSITION; BIOELECTRICAL IMPEDANCE ANALYSIS; BIOELECTRICAL POTENTIALS; CYSTIC FIBROSIS; GENOTYPE;
D O I
10.1097/00005176-199305000-00017
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The put-pose of this study was to measure whole-body bioelectrical variables and to validate the technique of bioelectrical impedance analysis (BIA) as a measure of total body water (TBW) in patients with cystic fibrosis (CF). In 20 normally nourished males with CF, aged 7 to 39 years, bioelectrical impedance measurements were compared with TBW measured by isotopic distribution of (H2O)-O-18. The relationship between the two measurements was found to be highly significant (r = 0.96; p < 0.0001). The major genotype mutation DELTAF508, was found to have no effect on BIA. Comparison of the CF patients with 21 normal controls matched for age and TBW volumes as measured by (H2O)-O-18 volume of distribution showed no difference in electrical parameters. However, the slope of the regression lines ((H2O)-O-18, H-2/R) was significantly steeper for the CF subjects (p < 0.03) than for controls. These data show that BIA can be used to measure TBW in patients with CF. However, the predictive equations developed in healthy control subjects should not be used; rather, separate predictive equations for patients with CF will need to be developed.
引用
收藏
页码:440 / 445
页数:6
相关论文
共 50 条
  • [1] MULTIPLE FREQUENCY BIOELECTRICAL-IMPEDANCE FOR THE PREDICTION OF TOTAL-BODY POTASSIUM IN CYSTIC-FIBROSIS
    QUIRK, P
    WARD, LC
    THOMAS, BJ
    HOLT, TL
    SHEPHERD, RW
    CORNISH, BH
    CLINICAL NUTRITION, 1995, 14 (06) : 348 - 353
  • [2] ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS
    KUSHNER, RF
    SCHOELLER, DA
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (03): : 417 - 424
  • [3] Assessment of bioelectrical impedance analysis for the prediction of total body water in cystic fibrosis
    Richards, ML
    Bell, SC
    Edmiston, KA
    Davies, PSW
    ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2003, 12 (02) : 161 - 165
  • [4] TOTAL-BODY POTASSIUM IN CYSTIC-FIBROSIS
    SHEPHERD, RW
    HOLT, TL
    GREER, R
    CLEGHORN, GJ
    THOMAS, BJ
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1989, 9 (02): : 200 - 205
  • [5] CAN BIOELECTRICAL-IMPEDANCE BE USED TO MEASURE TOTAL-BODY WATER IN DIALYSIS PATIENTS
    THOMPSON, CM
    KONG, CH
    LEWIS, CA
    HILL, PD
    THOMPSON, FD
    PHYSIOLOGICAL MEASUREMENT, 1993, 14 (04) : 455 - 461
  • [6] THE USE OF BIOELECTRICAL-IMPEDANCE ANALYSIS TO PREDICT TOTAL-BODY WATER IN PATIENTS WITH CANCER CACHEXIA
    SIMONS, JPFHA
    SCHOLS, AMWJ
    WESTERTERP, KR
    TENVELDE, GPM
    WOUTERS, EFM
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (04): : 741 - 745
  • [7] ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS IN BLACKS
    ZILLIKENS, MC
    CONWAY, JM
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 1991, 3 (01) : 25 - 32
  • [8] THE VALIDITY OF BIOELECTRICAL IMPEDANCE ANALYSIS IN ESTIMATING TOTAL-BODY WATER IN PATIENTS WITH CIRRHOSIS
    ZILLIKENS, MC
    VANDENBERG, JWO
    WILSON, JHP
    RIETVELD, T
    SWART, GR
    JOURNAL OF HEPATOLOGY, 1992, 16 (1-2) : 59 - 65
  • [9] ABNORMAL TOTAL-BODY POTASSIUM IN CYSTIC-FIBROSIS
    SOUTTER, V
    WATERS, D
    BLAGOJEVIC, N
    ALLEN, B
    PARSONS, D
    GRUCA, M
    GASKIN, K
    AUSTRALIAN PAEDIATRIC JOURNAL, 1987, 23 (06): : 385 - 386
  • [10] DETERMINATION OF TOTAL-BODY WATER IN UREMIC PATIENTS BY BIOELECTRICAL-IMPEDANCE
    KONG, CH
    THOMPSON, CM
    LEWIS, CA
    HILL, PD
    THOMPSON, FD
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1993, 8 (08) : 716 - 719