Test methods and test results concerning the measurement of chemical durability of glass media proposed for nuclear waste fixation are described. In order to develop predictive models and risk calculations, the release rates of individual components are measured. The results are used to determine matrix dissolution rates, possible transport of components through the matrix, and chemical and physical corrosion mechanisms. Measurements on model borosilicate and high silica glass fixation media are reported.