MODELS OF THE HUMAN BRAIN AND THE SURROUNDING MEDIA - THEIR INFLUENCE ON THE RELIABILITY OF SOURCE LOCALIZATION

被引:26
作者
FENDER, DH [1 ]
机构
[1] CALTECH, DIV BIOL, PASADENA, CA 91125 USA
关键词
SOURCE LOCALIZATION; HOMOGENEOUS SPHERE MODEL; SPHERICAL 3-SHELL MODEL; FINITE ELEMENT MODEL;
D O I
10.1097/00004691-199110000-00003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This article is a review of the evolution of models of the head as used in dipole source localization. Models fall into two classes: those that can be expressed in simple analytic form, such as the homogeneous sphere or spherical three-shell models, or those that can only be solved by numerical methods, such as the finite element approach. The latter models always involve heavy procedural and computational burdens. The trend over the last decade has been to use these more advanced models to estimate the error that would be incurred if one of the simpler spherical models were used instead for dipole source localization. An estimate is presented of the magnitudes of the random and systematic errors of localization that may be expected when using these methods.
引用
收藏
页码:381 / 390
页数:10
相关论文
共 42 条
[1]   A METHOD FOR LOCATING SCALP ELECTRODES IN SPHERICAL COORDINATES [J].
ARY, JP ;
DARCEY, TM ;
FENDER, DH .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (12) :834-836
[2]   APPLICATION OF ELECTROMAGNETIC THEORY TO ELECTROCARDIOLOGY .2. NUMERICAL SOLUTION OF INTEGRAL EQUATIONS [J].
BARNARD, ACL ;
DUCK, IM ;
LYNN, MS ;
TIMLAKE, WP .
BIOPHYSICAL JOURNAL, 1967, 7 (05) :463-&
[3]  
Brazier MAB, 1949, ELECTROEN CLIN NEURO, V2, p38 52
[4]   MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN [J].
COHEN, D ;
CUFFIN, BN ;
YUNOKUCHI, K ;
MANIEWSKI, R ;
PURCELL, C ;
COSGROVE, GR ;
IVES, J ;
KENNEDY, JG ;
SCHOMER, DL .
ANNALS OF NEUROLOGY, 1990, 28 (06) :811-817
[5]   TESTS OF EEG LOCALIZATION ACCURACY USING IMPLANTED SOURCES IN THE HUMAN BRAIN [J].
CUFFIN, BN ;
COHEN, D ;
YUNOKUCHI, K ;
MANIEWSKI, R ;
PURCELL, C ;
COSGROVE, GR ;
IVES, J ;
KENNEDY, J ;
SCHOMER, D .
ANNALS OF NEUROLOGY, 1991, 29 (02) :132-138
[6]   EFFECTS OF HEAD SHAPE ON EEGS AND MEGS [J].
CUFFIN, BN .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :44-52
[7]  
DARCEYN TM, 1979, THESIS CALTECH PASAD
[8]   AN ANALYTIC METHOD TO DETERMINE THE EFFECT OF SOURCE MODELING ERRORS ON THE APPARENT LOCATION AND DIRECTION OF BIOLOGICAL SOURCES [J].
DEMUNCK, JC ;
VANDIJK, BW ;
SPEKREIJSE, H .
JOURNAL OF APPLIED PHYSICS, 1988, 63 (03) :944-956
[9]   SURFACE EEG IN RELATION TO ITS SOURCES [J].
GEISLER, CD ;
GERSTEIN, GL .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1961, 13 (06) :927-&
[10]  
GESELOWITZ D. B., 1966, P393