The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers

被引:23
作者
Beeler, Nadja [1 ]
Roos, Lilian [1 ]
Delves, Simon K. [2 ]
Veenstra, Bertil J. [3 ]
Friedl, Karl [4 ]
Buller, Mark J. [4 ]
Wyss, Thomas [1 ]
机构
[1] Swiss Fed Inst Sport SFISM, Bern, Switzerland
[2] Inst Naval Med, Alverstoke, Hants, England
[3] Royal Netherlands Army, Inst Training Med & Training Physiol, TGTF, Utrecht, Netherlands
[4] US Army Res Inst Environm Med, Natick, MA USA
来源
IISE TRANSACTIONS ON OCCUPATIONAL ERGONOMICS & HUMAN FACTORS | 2018年 / 6卷 / 01期
关键词
Wearable devices; device placement; army; questionnaire; usability/acceptance; measurement and research;
D O I
10.1080/24725838.2018.1435431
中图分类号
TB18 [人体工程学];
学科分类号
1201 ;
摘要
Background: Military organizations use body-worn devices for ambulatory monitoring of physical activity in soldiers. However, little is known regarding the wearing comfort and acceptability of ambulatory monitoring devices as used in the military context. Purpose: To investigate the wearing comfort and acceptability of nine body-worn devices for monitoring physical activity in soldiers. Methods: A total of 27 male volunteers wore three randomly assigned devices simultaneously for one day of basic military training. The participants then completed a questionnaire designed to assess comfort and acceptability. Results: Devices worn on or around the chest were associated with lower wearing comfort and acceptability scores (overall scores of 59.7, 70.8, and 80.9 for Hidalgo EQ02, TICKR X, and ActiHeart, respectively). Devices worn around the wrist, Mio FUSE (80.9), GENEActiv (81.3), and fenix 3 (85.3), had mid-range scores. The highest scores were obtained for the devices Blue Thunder, worn on the shoe (85.5), Axiamote PADIS 2.0, worn on the hip and the backpack (88.9), and Everion, worn on the upper arm (90.1). Conclusions: Body-worn devices for monitoring physical activity are well-accepted in soldiers. The differences between the devices were small for several parameters. Nevertheless, devices that are attached to, or around, the chest, were typically perceived as having a slightly more negative impact on the body. Both wrist- and chest-worn devices received some reports of interfering with military equipment or military tasks.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 20 条
[1]   Body-Worn Sensor Design: What Do Patients and Clinicians Want? [J].
Bergmann, J. H. M. ;
McGregor, A. H. .
ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (09) :2299-2312
[2]   Wearable and Implantable Sensors: The Patient's Perspective [J].
Bergmann, Jeroen H. M. ;
Chandaria, Vikesh ;
McGregor, Alison .
SENSORS, 2012, 12 (12) :16695-16709
[3]   The physical demands upon (Dutch) fire-fighters in relation to the maximum acceptable energetic workload [J].
Bos, J ;
Mol, E ;
Visser, B ;
Frings-Dresen, MHW .
ERGONOMICS, 2004, 47 (04) :446-460
[4]   Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walking [J].
Bouten, CVC ;
Sauren, AAHJ ;
Verduin, M ;
Janssen, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) :50-56
[5]   A Comparison of Energy Expenditure Estimation of Several Physical Activity Monitors [J].
Dannecker, Kathryn L. ;
Sazonova, Nadezhda A. ;
Melanson, Edward L. ;
Sazonov, Edward S. ;
Browning, Raymond C. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (11) :2105-2112
[6]  
Federal Department of Defence Civil Protection and Sport DDPS, 2017, ARM ZAHL EFF ARM
[7]   Feasibility of three wearable sensors for 24 hour monitoring in middle-aged women [J].
Huberty, Jennifer ;
Ehlers, Diane K. ;
Kurka, Jonathan ;
Ainsworth, Barbara ;
Buman, Matthew .
BMC WOMENS HEALTH, 2015, 15
[8]   A tool to assess the comfort of wearable computers [J].
Knight, JF ;
Baber, C .
HUMAN FACTORS, 2005, 47 (01) :77-91
[9]   Validity of Consumer-Based Physical Activity Monitors [J].
Lee, Jung-Min ;
Kim, Youngwon ;
Welk, Gregory J. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (09) :1840-1848
[10]  
Mclntosh G.W.J., 2016, DRDCRDDC2016R152