Long-term visual outcomes after Crystalens (R) HD intraocular lens implantation

被引:3
作者
Karavitaki, Alexandra E. [1 ]
Pallikaris, Ioannis G. [1 ]
Panagopoulou, Sophia I. [1 ]
Kounis, George A. [1 ]
Kontadakis, George [1 ]
Kymionis, George D. [1 ]
机构
[1] Univ Crete, Inst Vis & Opt, Iraklion, Greece
关键词
presbyopia; accommodation;
D O I
10.2147/OPTH.S57009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Our purpose was to evaluate the long-term visual outcomes after bilateral implantation of Crystalens (R) HD (Bausch and Lomb, Inc.) accommodative intraocular lenses. Methods: In this study, 25 patients (50 eyes) who underwent cataract surgery and bilateral Crystalens HD accommodative intraocular lens implantation were included. The Crystalens HD lens was implanted in the bag in both eyes, without any intra-or postoperative complications. The visual parameters measured before and after surgery were: uncorrected distance visual acuity, corrected distance visual acuity (CDVA) (using the Early Diabetic Retinopathy Study [EDTRS] logMAR charts), uncorrected intermediate visual acuity, and uncorrected near visual acuity using a Birkhauser reading chart, at a distance of 66 cm and 33 cm for intermediate and near vision, respectively, directly illuminated by a lamp of 60 watts. After surgery, the patients were evaluated at 1, 3, 6, 12, 24, and 36 months. Results: The mean age was 68.70 +/- 7.1 (range: 54 to 83) years. The mean follow-up was 42.72 +/- 0.49 (range: 42.33 to 43.27) months. The uncorrected distance visual acuity improved from 0.56 +/- 0.41 (range: 0 to 2) preoperatively to 0.19 +/- 0.13 (range: 0 to 0.38) (logMAR scale) at the last follow-up visit, and the CDVA improved from 0.17 +/- 0.18 (range: 0 to 0.7) preoperatively to 0.05 +/- 0.05 (range: -0.02 to 0.22) at the last follow-up visit. No eyes lost lines of CDVA during the follow-up period, while 54% of patients gained one or more lines of CDVA. The uncorrected intermediate and near visual acuity was J2 or better in 71% and 69% of our patients, respectively. Conclusion: Crystalens HD implantation seems to provide an improvement in visual acuity for far, intermediate, and near distances.
引用
收藏
页码:937 / 943
页数:7
相关论文
共 25 条
[1]  
Alio JL, 2006, J REFRACT SURG, V22, P453
[2]  
Bellucci Roberto, 2005, Curr Opin Ophthalmol, V16, P33, DOI 10.1097/00055735-200502000-00006
[3]   Visual Outcomes and Safety of a Small Diameter Intrastromal Refractive Inlay for the Corneal Compensation of Presbyopia [J].
Bouzoukis, Dimitrios I. ;
Kymionis, George D. ;
Panagopoulou, Sophia I. ;
Diakonis, Vasilios F. ;
Pallikaris, Aristophanes I. ;
Limnopoulou, Aliki N. ;
Portaliou, Dimitra M. ;
Pallikaris, Ioannis G. .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) :168-U92
[4]   Experience with an accommodating IOL [J].
Cumming, JS ;
Kammann, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (08) :1001-1001
[5]  
Detorakis ET, 2013, INT OPHTHALMOL
[6]  
Dick H Burkhard, 2005, Curr Opin Ophthalmol, V16, P8, DOI 10.1097/00055735-200502000-00004
[7]   Early visual results with the ICU accommodating intraocular lens [J].
Dogru, M ;
Honda, R ;
Omoto, M ;
Toda, I ;
Fujishima, H ;
Arai, H ;
Matsuyama, M ;
Nishijima, S ;
Hida, Y ;
Yagi, Y ;
Tsubota, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :895-902
[8]   Presbyopia Treatment by Monocular Peripheral PresbyLASIK [J].
Epstein, Robert Leonard ;
Gurgos, Mark Andrew .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (06) :516-523
[9]   Initial experience with an accommodating intraocular lens: Controlled prospective study [J].
Hantera, Mohamed M. ;
Hamed, AbdelMonem M. ;
Fekry, Yousri ;
Shoheib, Essam Aldin .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07) :1167-1172
[10]   Pseudoaccommodation and visual acuity with technovision presbyLASIK and a theoretical simulated Array® multifocal intraocular lens [J].
Illueca, Carlos ;
Alio, Jorge L. ;
Mas, David ;
Ortiz, Dolores ;
Perez, Jorge ;
Espinosa, J. ;
Sala, Esperanza .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (04) :344-349