STUDIES EVALUATING THE APPLICABILITY OF UTILIZING THE SAME CONCENTRATION TECHNIQUES FOR THE DETECTION OF PROTOZOAN PARASITES AND VIRUSES IN WATER

被引:17
作者
KFIR, R
HILNER, C
DUPREEZ, M
BATEMAN, B
机构
[1] Division of Water Technology, CSIR, Pretoria, 0001
关键词
GIARDIA; CRYPTOSPORIDIUM; ENTERIC VIRUSES; FLAT BED FILTRATION; CARTRIDGE FILTER; ULTRAFILTRATION;
D O I
10.1016/0273-1223(95)00303-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study concentration techniques regularly used for viral detection; i.e. flat-bed ultrafiltration and Filterite cartridge filtration, were evaluated for their efficacies in the recovery of protozoan parasites from water. Recovery of cysts was studied using tap water seeded with Giardia muris cysts and compared to methods designed for the detection of protozoan parasites. Recovery of cysts utilizing 1.2 mu m membrane filters was 11.1% (4.5-23%) compared to 11.6% (2.7-25.5%) with ultrafiltration (pore size 46-50 Angstrom, with a molecular cut off of 50 000 daltons). Comparison of these methods for the isolation of Giardia cysts and Cryptosporidium oocysts from environmental water samples also indicated a similar efficacy. The recovery of cysts from 1001 of seeded samples using a Cuno wynd cartridge filter was 12.2% (1.6-45%) compared to 13.4% (5-24.2%) using a Filterite cartridge filter. Although the results indicated similar recovery efficacies for these two methods, use of Filterite resulted in a more consistent recovery rate. This study also indicated that the use of cartridge filters for the processing of large volume water samples (1001) showed a slightly better recovery efficacy than the flat-bed filtration technique which limits sample volume to about 101. This study shows that concentration techniques utilised for the isolation of enteric viruses can also be applied for the detection of protozoan parasites from water. This procedure allows for co-analysis of both viruses and protozoan parasites and provides a more rapid and cost-effective evaluation of water quality.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 18 条
[1]   COMPARISON OF THE IN-LINE INJECTOR AND FLUID PROPORTIONER USED TO CONDITION WATER SAMPLES FOR VIRUS MONITORING [J].
DAHLING, DR ;
WRIGHT, BA .
JOURNAL OF VIROLOGICAL METHODS, 1987, 18 (01) :67-71
[2]   CONCENTRATION OF VIRUSES FROM LARGE VOLUMES OF TAP WATER USING PLEATED MEMBRANE FILTERS [J].
FARRAH, SR ;
GERBA, CP ;
WALLIS, C ;
MELNICK, JL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1976, 31 (02) :221-226
[3]  
HIBLER CP, 1990, DRINKING WATER MICRO, P294
[4]   RECOVERY OF GIARDIA CYSTS FROM WATER - CENTRIFUGATION VS FILTRATION [J].
HOLMAN, B ;
FROST, F ;
PLAN, B ;
FUKUTAKI, K ;
JAKUBOWSKI, W .
WATER RESEARCH, 1983, 17 (11) :1705-1707
[5]  
JAKUBOWSKI W, 1978, J AM WATER WORKS ASS, V70, P702
[6]   OCCURRENCE OF GIARDIA AND CRYPTOSPORIDIUM SPP IN SURFACE-WATER SUPPLIES [J].
LECHEVALLIER, MW ;
NORTON, WD ;
LEE, RG .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (09) :2610-2616
[7]   OCCURRENCE OF CRYPTOSPORIDIUM OOCYSTS IN SEWAGE EFFLUENTS AND SELECTED SURFACE WATERS [J].
MADORE, MS ;
ROSE, JB ;
GERBA, CP ;
ARROWOOD, MJ ;
STERLING, CR .
JOURNAL OF PARASITOLOGY, 1987, 73 (04) :702-705
[8]   DETECTION OF CRYPTOSPORIDIUM IN WATER BY USING POLYPROPYLENE CARTRIDGE FILTERS [J].
MUSIAL, CE ;
ARROWOOD, MJ ;
STERLING, CR ;
GERBA, CP .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1987, 53 (04) :687-692
[9]  
NUPEN EM, 1981, PROG WATER TECHNOL, V13, P851
[10]  
ONGERTH JE, 1987, APPL ENVIRON MICROB, V53, P672