DETERMINATION OF STRESS LEVELS AND PROFILES IN THE PERIODONTAL-LIGAMENT BY MEANS OF AN IMPROVED 3-DIMENSIONAL FINITE-ELEMENT MODEL FOR VARIOUS TYPES OF ORTHODONTIC AND NATURAL FORCE SYSTEMS

被引:49
作者
ANDERSEN, KL [1 ]
MORTENSEN, HT [1 ]
PEDERSEN, EH [1 ]
MELSEN, B [1 ]
机构
[1] UNIV AALBORG,DEPT SOLID MECH,DK-9220 AALBORG 0,DENMARK
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1991年 / 13卷 / 04期
关键词
3D-FINITE ELEMENT; STRUCTURE OPTIMIZATION; PERIODONTAL LIGAMENT; STRESS-STRAIN; ORTHODONTICS; MULTIPLE MODELING;
D O I
10.1016/0141-5425(91)90111-J
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study was undertaken to investigate the stress-strain levels and distribution within the periodontal ligament for various types of physiological and orthodontic force systems, assuming that the bone resorption process, leading to tooth movements, is partly controlled by those conditions. Two finite element models were developed, simulating a full and partial mandibular morphology, respectively. Both models were based on morphology and physical parameters of human autopsy material. The effect of changing material parameters and type of boundary conditions, calculation method and fineness of the model on the stress levels and profiles in the periodontal ligament was evaluated by a series of tests. A structure optimization technique was used to investigate the load bearing characteristics of the mandible and the influence of the anisotropic material properties of both the mandible and the segment. A 'multiple modelling' technique based on both the mandible and the segment was developed to test various types of boundary conditions in the analysis of the segment. Results presented as 'stress profiles' showing the correlation between the applied force system and the stress distribution in the periodontal ligament, based on the improved finite element models, were established.
引用
收藏
页码:293 / 303
页数:11
相关论文
共 26 条
[1]  
BAUMRIND A, 1969, AM J ORTHOD, V55, P12
[2]  
Burstone C, 1985, ORTHODONTICS CURRENT, P193
[3]  
Burstone CJ, 1962, VISTAS ORTHODONTICS, P197
[4]  
CAPUTO AA, 1987, BIOMECHANICS CLIN DE
[5]  
CARLSOO S, 1952, ACTA ODONTOL SCAND, V10, P65
[6]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[7]  
CARTER DR, 1978, CLIN ORTHOP RELAT R, V135, P192
[8]  
CURREY J, 1984, MECHANICAL ADAPTIONS
[9]   ELECTRIC CURRENTS, BONE REMODELING, AND ORTHODONTIC TOOTH MOVEMENT .1. EFFECT OF ELECTRIC CURRENTS ON PERIODONTAL CYCLIC-NUCLEOTIDES [J].
DAVIDOVITCH, Z ;
FINKELSON, MD ;
STEIGMAN, S ;
SHANFELD, JL ;
MONTGOMERY, PC ;
KOROSTOFF, E .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 77 (01) :14-32
[10]   CYCLIC-AMP LEVELS IN ALVEOLAR BONE OF ORTHODONTICALLY-TREATED CATS [J].
DAVIDOVITCH, Z ;
SHANFELD, JL .
ARCHIVES OF ORAL BIOLOGY, 1975, 20 (09) :567-&