DETECTION EFFICIENCY OF THE NEUTRON MODULAR DETECTOR DEMON AND RELATED CHARACTERISTICS

被引:113
作者
TILQUIN, I
ELMASRI, Y
PARLOG, M
COLLON, P
HADRI, M
KEUTGEN, T
LEHMANN, J
LELEUX, P
LIPNIK, P
NINANE, A
HANAPPE, F
BIZARD, G
DURAND, D
MOSRIN, P
PETER, J
REGIMBART, R
TAMAIN, B
机构
[1] UNIV CATHOLIQUE LOUVAIN,INST PHYS NUCL,B-1348 LOUVAIN,BELGIUM
[2] UNIV CATHOLIQUE LOUVAIN,FNRS,B-1348 LOUVAIN,BELGIUM
[3] FREE UNIV BRUSSELS,B-1050 BRUSSELS,BELGIUM
[4] ISMRA UNIV,IN2P3,PHYS CORPUSCULAIRE LAB,CNRS,F-14050 CAEN,FRANCE
关键词
D O I
10.1016/0168-9002(95)00425-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
DEMON is a detector array for neutrons emitted in heavy ion induced reactions at low to intermediate energies. The neutron detection efficiency of some single DEMON modules has been measured in the energy range 8-21 MeV, with detection thresholds down to 0.1 MeV equivalent-electron (MeVee). The influence on the efficiency of cross talk, neutron-gamma and neutron-charged particle discrimination techniques was found to be negligibly small. Monte Carlo simulations have been performed and are compared with the experimental data. The relative weight of the interaction channel C-12(n,n'gamma) in the organic liquid scintillator was determined experimentally. Taking into account observed saturation effects in the detector output, a calibration method is proposed for high light outputs, based on the energy loss of cosmic ray muons.
引用
收藏
页码:446 / 461
页数:16
相关论文
共 12 条
[1]  
ADACHOUR A, 1990, THESIS U CATHOLIQUE
[2]   A NOVEL DESIGN FOR A FAST INTENSE NEUTRON BEAM [J].
BOL, A ;
LELEUX, P ;
LIPNIK, P ;
MACQ, P ;
NINANE, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3) :169-173
[3]   IMPROVED PREDICTIONS OF NEUTRON DETECTION EFFICIENCY FOR HYDROCARBON SCINTILLATORS FROM 1 MEV TO ABOUT 300 MEV [J].
CECIL, RA ;
ANDERSON, BD ;
MADEY, R .
NUCLEAR INSTRUMENTS & METHODS, 1979, 161 (03) :439-447
[4]  
LEO WR, 1987, TECHNIQUES NUCLEAR P
[5]  
LOHMANN W, 1985, CERN8503 EXPT PHYS D
[6]   NEUTRON-SPECTRA OF AM-241-B, AM-241-BE, AM-241-F, CM-242-BE, PU-238-C-13 AND CF-252 ISOTOPIC NEUTRON SOURCES [J].
LORCH, EA .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1973, 24 (10) :585-591
[7]   RESPONSE OF NE-228A, NE-228, NE-224, AND NE-102 SCINTILLATORS TO PROTONS FROM 2.43 TO 19.55 MEV [J].
MADEY, R ;
WATERMAN, FM ;
BALDWIN, AR ;
KNUDSON, JN ;
CARLSON, JD ;
RAPAPORT, J .
NUCLEAR INSTRUMENTS & METHODS, 1978, 151 (03) :445-450
[8]   STUDY OF N-GAMMA DISCRIMINATION BY DIGITAL CHARGE COMPARISON METHOD FOR A LARGE VOLUME LIQUID SCINTILLATOR [J].
MOSZYNSKI, M ;
BIZARD, G ;
COSTA, GJ ;
DURAND, D ;
ELMASRI, Y ;
GUILLAUME, G ;
HANAPPE, F ;
HEUSCH, B ;
HUCK, A ;
PETER, J ;
RING, C ;
TAMAIN, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (1-2) :262-272
[9]   COMPARATIVE-STUDY OF NEW 130-MM DIAMETER FAST PHOTOMULTIPLIERS FOR NEUTRON DETECTORS [J].
MOSZYNSKI, M ;
COSTA, GJ ;
GUILLAUME, G ;
HEUSCH, B ;
HUCK, A ;
MOUATASSIM, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (01) :97-109
[10]  
STANTON NR, 1971, COO154592