ULTRASOUND-GUIDED CORE BIOPSY OF THORACIC TUMORS

被引:66
作者
YANG, PC
CHANG, DB
YU, CJ
LEE, YC
WU, HD
KUO, SH
LUH, KT
机构
[1] NATL TAIWAN UNIV HOSP,DEPT CLIN PATHOL,TAIPEI 100,TAIWAN
[2] ACAD SINICA,INST BIOMED SCI,TAIPEI 115,TAIWAN
[3] NATL TAIWAN UNIV HOSP,DEPT SURG,TAIPEI 100,TAIWAN
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1992年 / 146卷 / 03期
关键词
D O I
10.1164/ajrccm/146.3.763
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Two hundred and eighteen patients, with thoracic tumors larger than 3 cm in size, underwent ultrasound-guided percutaneous transthoracic core biopsy with a large-bore Tru-Cut needle. Fifty-five tumors were in the mediastinum, and 122 tumors were located at subpleural area, and 42 tumors were within the lungs. In 122 subpleural tumors, the sensitivity of ultrasound-guided core biopsy for the diagnosis of malignancy was 96.8%, and accuracy was 97.5%. Sensitivity for the diagnosis of malignant tumors located within the lungs was 94.6%, and accuracy was 95.2%. In 54 patients with mediastinal tumors, definite histologic diagnosis could be obtained in 48 patients (88.9%). The sensitivity of ultrasound-guided biopsy for the diagnosis of malignancy in these 48 mediastinal tumors was 97.1%, with an accuracy of 97.9%. Three patients had complications with minimal pneumothorax and one with mild hemoptysis. We conclude that percutaneous transthoracic core biopsy with Tru-Cut needle under ultrasound guidance is a safe and sensitive way to obtain specimens for accurate histologic diagnosis of thoracic tumors. The diagnostic yield is high, and the technique, relatively simple, can also be used for outpatients.
引用
收藏
页码:763 / 767
页数:5
相关论文
共 17 条
[1]   ULTRASONICALLY GUIDED PERCUTANEOUS BIOPSY OF PERIPHERAL PULMONARY MASSES [J].
CHANDRASEKHAR, AJ ;
REYNES, CJ ;
CHURCHILL, RJ .
CHEST, 1976, 70 (05) :627-630
[2]   CT AND SONOGRAPHICALLY GUIDED NEEDLE-BIOPSY - CURRENT TECHNIQUES AND NEW INNOVATIONS [J].
CHARBONEAU, JW ;
READING, CC ;
WELCH, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (01) :1-10
[3]   ANTERIOR MEDIASTINAL MASSES - UTILITY OF TRANSTHORACIC NEEDLE-BIOPSY [J].
HERMAN, SJ ;
HOLUB, RV ;
WEISBROD, GL ;
CHAMBERLAIN, DW .
RADIOLOGY, 1991, 180 (01) :167-170
[4]   PERCUTANEOUS BIOPSY OF THORACIC LESIONS - VALUE OF SONOGRAPHY FOR NEEDLE GUIDANCE [J].
IKEZOE, J ;
MORIMOTO, S ;
ARISAWA, J ;
TAKASHIMA, S ;
KOZUKA, T ;
NAKAHARA, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (06) :1181-1185
[5]  
JENNINGS PE, 1989, LANCET, V1, P1369
[6]   US GUIDANCE OF INTERVENTIONAL PROCEDURES [J].
MATALON, TAS ;
SILVER, B .
RADIOLOGY, 1990, 174 (01) :43-47
[7]   GUIDELINES FOR PERCUTANEOUS TRANS-THORACIC NEEDLE-BIOPSY [J].
SOKOLOWSKI, JW ;
BURGHER, LW ;
JONES, FL ;
PATTERSON, JR ;
SELECKY, PA .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (01) :255-256
[8]  
WEISBROD GL, 1990, RADIOL CLIN N AM, V28, P647
[9]   PRELIMINARY EXPERIENCE WITH A DUAL CUTTING EDGE NEEDLE IN THORACIC PERCUTANEOUS FINE-NEEDLE ASPIRATION BIOPSY [J].
WEISBROD, GL ;
HERMAN, SJ ;
TAO, LC .
RADIOLOGY, 1987, 163 (01) :75-78
[10]   MEDIASTINAL TUMORS - BIOPSY UNDER US GUIDANCE [J].
WERNECKE, K ;
VASSALLO, P ;
PETERS, PE ;
VONBASSEWITZ, DB .
RADIOLOGY, 1989, 172 (02) :473-476