A BIOMECHANICAL COMPARISON OF 2 METHODS OF FIXATION OF FRACTURES OF THE FOREARM

被引:39
作者
JONES, DJ [1 ]
HENLEY, MB [1 ]
SCHEMITSCH, EH [1 ]
TENCER, AF [1 ]
机构
[1] UNIV WASHINGTON,DEPT ORTHOPED,HARBORVIEW BIOMECH LAB,SEATTLE,WA 98195
关键词
FOREARM FRACTURES; BIOMECHANICS; INTERNAL FIXATION; INTRAMEDULLARY RODDING;
D O I
10.1097/00005131-199506000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In this study two different types of forearm internal fracture fixations were compared: limited-contact dynamic compression (DC) plates and fluted intramedullary (IM) rods. Eight matched pairs of intact forearms, consisting of the distal part of the humerus, elbow joint, radius, ulna, interosseus membrane, wrist joint, and metacarpals, were randomly separated into two groups. Each was placed into a custom-designed apparatus and subjected to medial bending, supination, pronation, axial compression, and distraction loading. Loads were applied by a materials testing system, and angular displacements were measured by inclinometers. The procedure consisted of first testing specimens intact, then retesting after oseotomizing and fixing the radius with either a plate or rod in half of the group and retesting after oseotomizing and fixing the ulna in the other half. Testing was continued by osteotomizing the remaining intact bone to create a two-bone fracture, fixing them, and retesting after creating a 5-mm gap at the osteotomy sites. These tests showed that the intact ulna contributes more to forearm stability in bending and torsion than does the radius. Therefore, if the radius is fractured but the ulna remains intact, LM redding will produce constructs with greater stiffnesses, particularly in torsion, than if the ulna is fractured and the radius is intact. In the case of a two-bone fracture, implantation of rods will result in a construct with significantly less stiffness in torsion, as well as distraction and compression (in the case of a fracture gap), than if the fractures were plated. The torsional stiffness with rod fixation was low with a two-bone fracture (2.23% of intact specimens) compared with fixation with plates (83.4% of intact specimens) and the resistance to distraction and compression small (5-10 N of axial load). Consideration might be given to supplemental stabilization if IM rods are used in these circumstances.
引用
收藏
页码:198 / 206
页数:9
相关论文
共 17 条
[1]  
Anderson L.D., Sisk T.D., Tooms R.E., Park W.I., Compression plate fixation in acute diaphyseal fractures of the radius and ulna, J Bone Joint Surg [Am], 57, pp. 287-297, (1975)
[2]  
Bone L.B., Locked intramedullary nailing of tibial shaft fractures, Techniques Orthop, 3, pp. 47-53, (1988)
[3]  
Chao E.Y.S., Aro H.T., Lewallen D.G., Kelly P.J., The effect of rigidity on fracture healing in external fixation, Clin Orthop, 241, pp. 24-35, (1989)
[4]  
Chapman M., Closed intramedullary bone-grafting and nailing of segmental defects of the femur, J Bone Joint Surg [Am], 62, pp. 1004-1008, (1980)
[5]  
Clawson D.K., Smith R.F., Hansen S.T., Closed intramedullary nailing of the femur, J Bone Joint Surg [Am], 53, pp. 681-692, (1971)
[6]  
Dobozi W.R., Hall R.F., Flexible intramedullary nailing of humeral shaft fractures, The Science and Practise of Intramedullary Nailing, pp. 305-318, (1987)
[7]  
Gilbert J.A., Dahners L.E., Atkinson M.A., The effects of external fixation stiffness on early healing of transverse os-teotemies, J Orthop Res, 7, pp. 389-397, (1989)
[8]  
Hadden W.A., Reschauer R., Seggl W., Results of AO plate fixation of forearm shaft fractures in adults, Injury, 15, pp. 44-52, (1983)
[9]  
Hidaka S., Guistilo R.B., Refracture of bones of the forearm after plate removal, J Bone Joint Surg [Am], 66, pp. 1241-1243, (1984)
[10]  
Kowalski M., Schemitsch E.H., Senft D., Harrington R.M., Rampoldi E., Swiontkowski M.F., Comparative evaluation of the effect of plate design on fracture healing with special reference to cortical bone blood flow and biomechanical properties, Transactions of the 39Th ORS, 18, (1993)