THE DEVELOPMENT OF CONFORMAL RADIATION-THERAPY

被引:36
作者
FRAASS, BA
机构
[1] Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, 48105, Michigan
关键词
CONFORMAL THERAPY; TREATMENT PLANNING; 3-D; COMPUTER-CONTROL; MULTILEAF COLLIMATOR;
D O I
10.1118/1.597446
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The development and clinical use of conformal radiation therapy, and the application of modern computer-controlled radiation therapy treatment techniques to the delivery of conformal therapy, has been a major research area in the field of radiation oncology in recent years. The introduction of three-dimensional (3-D) patient imaging, 3-D treatment planning systems, computer-controlled treatment machines equipped with multileaf collimators, and the continuing increase in computer power and software sophistication has finally allowed the clinical implementation of the kinds of conformal treatment planning and delivery that were envisioned decades ago. The use of 3-D treatment planning in conjunction with conformal treatments and the analysis of clinical normal tissue complications has also begun to give the field the clinical complication (and eventually tumor control) probability data which can be used to truly optimize radiation treatments. At this centennial anniversary of the discovery of the x ray, it is appropriate to look back at the contributions which have led to the current developments in conformal therapy. Few if any of the ''new developments'' associated with modern computer-controlled conformal therapy (CCRT) are actually new. However, modern technology has finally progressed to the point that we can integrate all of the features that are necessary to really make the concepts work in the clinic. This paper traces some of the developments which have led to the current interest and progress in CCRT treatments. A brief summary of the current status of conformal therapy and the work still to be done is also included.
引用
收藏
页码:1911 / 1921
页数:11
相关论文
共 151 条
[1]   3-DIMENSIONAL CONFORMAL RADIATION-THERAPY MAY IMPROVE THE THERAPEUTIC RATIO OF HIGH-DOSE RADIATION-THERAPY FOR LUNG-CANCER [J].
ARMSTRONG, JG ;
BURMAN, C ;
LEIBEL, S ;
FONTENLA, D ;
KUTCHER, G ;
ZELEFSKY, M ;
FUKS, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04) :685-689
[2]   DOSE VOLUME HISTOGRAM ANALYSIS OF LIVER RADIATION TOLERANCE [J].
AUSTINSEYMOUR, MM ;
CHEN, GTY ;
CASTRO, JR ;
SAUNDERS, WM ;
PITLUCK, S ;
WOODRUFF, KH ;
KESSLER, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (01) :31-35
[3]  
BAUERKIRPES B, 1987, INT J RADIAT ONCOL, V13, P130
[4]   INTERACTIVE DIGITAL COMPUTER SYSTEM FOR RADIOTHERAPY TREATMENT PLANNING [J].
BENTLEY, RE ;
MILAN, J .
BRITISH JOURNAL OF RADIOLOGY, 1971, 44 (527) :826-&
[5]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[6]  
Boyer, 1995, Semin Radiat Oncol, V5, P146, DOI 10.1016/S1053-4296(95)80007-7
[7]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[8]   CONFORMATION THERAPY AT THE ROYAL FREE HOSPITAL - A PROGRESS REPORT ON THE TRACKING COBALT PROJECT [J].
BRACE, JA ;
DAVY, TJ ;
SKEGGS, DBL ;
WILLIAMS, HS .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (648) :1068-1074
[9]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[10]   ELECTRON AND PHOTON BEAMS FROM A 50 MEV RACETRACK MICROTRON [J].
BRAHME, A ;
KRAEPELIEN, T ;
SVENSSON, H .
ACTA RADIOLOGICA ONCOLOGY, 1980, 19 (04) :305-319