GLUCOSE BIOSENSOR BASED ON THE INCORPORATION OF MELDOLA BLUE AND GLUCOSE-OXIDASE WITHIN CARBON-PASTE

被引:32
作者
KULYS, J [1 ]
HANSEN, HE [1 ]
BUCHRASMUSSEN, T [1 ]
WANG, J [1 ]
OZSOZ, M [1 ]
机构
[1] NEW MEXICO STATE UNIV,DEPT CHEM & BIOCHEM,LAS CRUCES,NM 88003
关键词
BIOSENSORS; GLUCOSE; GLUCOSE OXIDASE; MELDOLA BLUE MEDIATOR;
D O I
10.1016/0003-2670(93)E0610-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The phenoxazine compound Meldola Blue (MB) is shown to efficiently mediate the electron transfer from reduced glucose oxidase to a conventional carbon paste electrode. The mediation process is exploited for developing an amperometric biosensor for glucose, which yields a linear response to 0-25 mM glucose at an operating potential of 50 mV (vs. SCE), where interfering reactions do not occur. Experimental variables such as enzyme loading or operating potential are explored. A stable response is observed over several months.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 17 条
[1]   PREPARATION AND CHARACTERIZATION OF A FRAGILE ENZYME IMMOBILIZED CARBON PASTE ELECTRODE [J].
AMINE, A ;
KAUFFMANN, JM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1992, 28 (1-2) :117-125
[2]  
BARTLETT P N, 1991, Progress in Reaction Kinetics, V16, P55
[3]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[4]  
BUCHRASMUSSEN T, 1992, Patent No. 7263
[5]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[6]  
CZABAN JD, 1985, ANAL CHEM, V57, pA345
[7]   CARBON PASTE-TETRATHIAFULVALENE AMPEROMETRIC ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE IN FLOWING SYSTEMS [J].
GUNASINGHAM, H ;
TAN, CH .
ANALYST, 1990, 115 (01) :35-39
[8]   INVESTIGATION OF VIOLOGEN DERIVATIVES AS ELECTRON-TRANSFER MEDIATORS IN AMPEROMETRIC GLUCOSE SENSORS [J].
HALE, PD ;
BOGUSLAVSKY, LI ;
KARAN, HI ;
LAN, HL ;
LEE, HS ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :155-161
[9]   AN ENZYME ELECTRODE FOR GLUCOSE CONSISTING OF GLUCOSE-OXIDASE IMMOBILIZED AT A BENZOQUINONE-MODIFIED CARBON ELECTRODE [J].
HU, J ;
TURNER, APF .
ANALYTICAL LETTERS, 1991, 24 (01) :15-24
[10]   AN AMPEROMETRIC GLUCOSE SENSOR MADE BY MODIFICATION OF A GRAPHITE ELECTRODE SURFACE WITH IMMOBILIZED GLUCOSE-OXIDASE AND ADSORBED MEDIATOR [J].
JONSSON, G ;
GORTON, L .
BIOSENSORS, 1985, 1 (04) :355-368