CHOOSING A TL-201 OR TECHNETIUM 99M SESTAMIBI IMAGING PROTOCOL

被引:6
作者
UDELSON, JE
机构
[1] TUFTS UNIV, SCH MED, DEPT MED, DIV CARDIOL, BOSTON, MA USA
[2] TUFTS UNIV, SCH MED, DEPT RADIOL, DIV NUCL MED, BOSTON, MA USA
关键词
THALLIUM; 201; SESTAMIBI; IMAGING PROTOCOLS;
D O I
10.1007/BF03032555
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During the past decade progress in the field of myocardial perfusion imaging has resulted in a myriad of choices for perfusion imaging protocols, including choices in types of stressor, imaging modality, perfusion tracer, method of analysis, and a wide range of choices of imaging protocols. This review will examine this latter aspect in the context of choices of perfusion tracers that are now available for wide use. Manipulations of thallium protocols have revolved primarily around optimizing identification of stress defect reversibility and regional myocardial viability. The high image quality and long retention time afforded by the technetium-labeled agents allow the potential for streamlining imaging protocols to maximize efficiency and cost-effectiveness, such as performing stress only imaging in a subset of patients and performing simultaneous assessment of perfusion and function.
引用
收藏
页码:S99 / S108
页数:10
相关论文
共 46 条
[1]   SEPARATE ACQUISITION REST THALLIUM-201/STRESS TC-99M SESTAMIBI DUAL-ISOTOPE MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - A CLINICAL VALIDATION-STUDY [J].
BERMAN, DS ;
KIAT, H ;
FRIEDMAN, JD ;
WANG, FP ;
VANTRAIN, K ;
MATZER, L ;
MADDAHI, J ;
GERMANO, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1455-1464
[2]  
BERMAN DS, 1993, CIRCULATION, V88, P486
[3]   COMPARISON OF SINGLE-DOSE AND DOUBLE-DOSE TL-201 MYOCARDIAL PERFUSION SCINTIGRAPHY FOR DETECTION OF CORONARY-ARTERY DISEASE AND PRIOR MYOCARDIAL-INFARCTION [J].
BLOOD, DK ;
MCCARTHY, DM ;
SCIACCA, RR ;
CANNON, PJ .
CIRCULATION, 1978, 58 (05) :777-788
[4]   IDENTIFICATION OF VIABLE MYOCARDIUM IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE AND LEFT-VENTRICULAR DYSFUNCTION - COMPARISON OF THALLIUM SCINTIGRAPHY WITH REINJECTION AND PET IMAGING WITH F-18 FLUORODEOXYGLUCOSE [J].
BONOW, RO ;
DILSIZIAN, V ;
CUOCOLO, A ;
BACHARACH, SL .
CIRCULATION, 1991, 83 (01) :26-37
[5]   EXERCISE-INDUCED ISCHEMIA IN MILDLY SYMPTOMATIC PATIENTS WITH CORONARY-ARTERY DISEASE AND PRESERVED LEFT-VENTRICULAR FUNCTION - IDENTIFICATION OF SUBGROUPS AT RISK OF DEATH DURING MEDICAL THERAPY [J].
BONOW, RO ;
KENT, KM ;
ROSING, DR ;
LAN, KKG ;
LAKATOS, E ;
BORER, JS ;
BACHARACH, SL ;
GREEN, MV ;
EPSTEIN, SE .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 311 (21) :1339-1345
[6]   PROGNOSTIC VALUE OF TL-201 MYOCARDIAL PERFUSION IMAGING - A DIAGNOSTIC-TOOL COMES OF AGE [J].
BROWN, KA .
CIRCULATION, 1991, 83 (02) :363-381
[7]   POSITRON EMISSION TOMOGRAPHY DETECTS TISSUE METABOLIC-ACTIVITY IN MYOCARDIAL SEGMENTS WITH PERSISTENT THALLIUM PERFUSION DEFECTS [J].
BRUNKEN, R ;
SCHWAIGER, M ;
GROVERMCKAY, M ;
PHELPS, ME ;
TILLISCH, J ;
SCHELBERT, HR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) :557-567
[8]   GATED TC-99M SESTAMIBI FOR SIMULTANEOUS ASSESSMENT OF STRESS MYOCARDIAL PERFUSION, POSTEXERCISE REGIONAL VENTRICULAR-FUNCTION AND MYOCARDIAL VIABILITY - CORRELATION WITH ECHOCARDIOGRAPHY AND REST TL-201 SCINTIGRAPHY [J].
CHUA, T ;
KIAT, H ;
GERMANO, G ;
MAURER, G ;
VANTRAIN, K ;
FRIEDMAN, J ;
BERMAN, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) :1107-1114
[9]  
DEPUEY E G, 1992, Journal of Nuclear Medicine, V33, P927
[10]   CONCORDANCE AND DISCORDANCE BETWEEN STRESS-REDISTRIBUTION-REINJECTION AND REST-REDISTRIBUTION THALLIUM IMAGING FOR ASSESSING VIABLE MYOCARDIUM - COMPARISON WITH METABOLIC-ACTIVITY BY POSITRON EMISSION TOMOGRAPHY [J].
DILSIZIAN, V ;
PERRONEFILARDI, P ;
ARRIGHI, JA ;
BACHARACH, SL ;
QUYYUMI, AA ;
FREEDMAN, NMT ;
BONOW, RO .
CIRCULATION, 1993, 88 (03) :941-952