ISOELECTRIC-FOCUSING OF PROTEINS IN A MICROCAPILLARY WITH UNIVERSAL CONCENTRATION GRADIENT DETECTION

被引:4
作者
WU, J [1 ]
PAWLISZYN, J [1 ]
机构
[1] UNIV WATERLOO,DEPT CHEM,WATERLOO N2L 3G1,ONTARIO,CANADA
关键词
CAPILLARY ISOELECTRIC FOCUSING; MICROCAPILLARY; CONCENTRATION GRADIENT DETECTOR; PROTEIN ANALYSIS;
D O I
10.1002/mcs.1220040509
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Proteins were separated by capillary isoelectric focusing (CIEF) performed in a 5-mum i.d., 12-cm long uncoated capillary, and detected by an on-column concentration gradient detector based on Schlieren optics. The narrow capillary allows the application of a 15-kV separation voltage. The high voltage resulted in a very narrow 30-mum wide zone for carbonic anhydrase, which corresponded to a 60-fL zone volume. All focused proteins could be detected by the universal concentration gradient detector without derivatization in less than 7 min. On-column mass detection limits for proteins were at the 100 amol level, which was lower than that of a UV-vis absorption spectrometric detector. The detection volume of the detector was calculated to be 20 fL, the smallest detection volumes reported to date for optical or spectroscopic detectors. This microcapillary CIEF-concentration gradient detector system may be a useful technique for direct analysis of proteins at the single cell level.
引用
收藏
页码:419 / 422
页数:4
相关论文
共 10 条
[1]   SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE [J].
CHENG, YF ;
DOVICHI, NJ .
SCIENCE, 1988, 242 (4878) :562-564
[2]   CAPILLARY ISOELECTRIC-FOCUSING OF PROTEINS IN UNCOATED FUSED-SILICA CAPILLARIES USING POLYMERIC ADDITIVES [J].
MAZZEO, JR ;
KRULL, IS .
ANALYTICAL CHEMISTRY, 1991, 63 (24) :2852-2857
[3]   CAPILLARY ISOTACHOPHORESIS WITH CONCENTRATION GRADIENT DETECTION [J].
MCDONNELL, T ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1884-1889
[4]   CAPILLARY ELECTROPHORESIS IN 2-MU-M AND 5-MU-M DIAMETER CAPILLARIES - APPLICATION TO CYTOPLASMIC ANALYSIS [J].
OLEFIROWICZ, TM ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1990, 62 (17) :1872-1876
[5]  
PAWLISZYN J, 1990, SPECTROCHIM ACTA REV, V13, P311
[6]   APPLICATION OF CAPILLARY ISOELECTRIC-FOCUSING WITH UNIVERSAL CONCENTRATION GRADIENT DETECTOR TO THE ANALYSIS OF PROTEIN SAMPLES [J].
WU, J ;
PAWLISZYN, J .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :121-130
[7]   HIGH-PERFORMANCE CAPILLARY ISOELECTRIC-FOCUSING WITH A CONCENTRATION GRADIENT DETECTOR [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :219-224
[8]   INDIRECT DETECTION METHODS FOR CAPILLARY SEPARATIONS [J].
YEUNG, ES ;
KUHR, WG .
ANALYTICAL CHEMISTRY, 1991, 63 (05) :A275-&
[9]   OPTIMIZING SEPARATION PARAMETERS IN CAPILLARY ISOELECTRIC-FOCUSING [J].
ZHU, MD ;
RODRIGUEZ, R ;
WEHR, T .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :479-488
[10]  
1991, J CHROMATOGR, V559