Delayed Rupture of Flexor Pollicis Longus after Volar Plating for a Distal Radius Fracture

被引:20
作者
Cho, Chul-Hyun [1 ]
Lee, Kyung-Jae [1 ]
Song, Kwang-Soon [1 ]
Bae, Ki-Cheor [1 ]
机构
[1] Keimyung Univ, Sch Med, Dongsan Med Ctr, Dept Orthopaed Surg, 56 Dalseong Ro, Daegu 700712, South Korea
关键词
Flexor pollicis longus; Distal radius fracture; Volar plating; Delayed rupture;
D O I
10.4055/cios.2012.4.4.325
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although extensor tendon rupture often occurs after volar plating for a distal radius fracture, a flexor tendon rupture is extremely rare. Most reported instances of flexor tendon ruptures after volar plating have involved improper placement of the plate, increased prominence of the distal edge of the plate because of collapse of the fracture site, use of custom-made plates, current steroid use by the patient, or a history of tendon injury. We report a case of delayed rupture of the flexor pollicis longus tendon 40 months after volar plating with a 3.5-mm T-locking compression plate for which the distal edge was located at the transverse ridge level of the distal radius. If symptoms such as tendon irritation occur in this situation, surgeons should consider removing the plate as soon as possible after bony union is achieved.
引用
收藏
页码:325 / 328
页数:4
相关论文
共 10 条
[1]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[2]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[3]   Flexor tendon injuries following locked volar plating of distal radius fractures [J].
Cross, Andrew W. ;
Schmidt, Christopher C. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02) :164-167
[4]  
Duncan Scott F M, 2007, Am J Orthop (Belle Mead NJ), V36, P669
[5]   Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: A case report [J].
Klug, Raymond A. ;
Press, Cyrus M. ;
Gonzalez, Mark H. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07) :984-988
[6]   DELAYED RUPTURE OF FLEXOR POLLICIS LONGUS TENDON AFTER VOLAR PLATING OF THE DISTAL RADIUS [J].
Koo, Siu Cheong ;
Ho, Sheung Tung .
JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2006, 11 (1-2) :67-70
[7]   Untitled [J].
Louis, DS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :353-353
[8]   Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the π plate on the volar surface of the distal radius [J].
Nunley, JA ;
Rowan, PR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1999, 24A (06) :1279-1280
[9]   Current concepts in volar fixed-angle fixation of unstable distal radius fractures [J].
Orbay, Jorge L. ;
Touhami, Amel .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (445) :58-67
[10]   Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate [J].
Schnur, DP ;
Chang, B .
ANNALS OF PLASTIC SURGERY, 2000, 44 (05) :564-566