ISOELECTRIC-FOCUSING OF PROTEINS IN CAPILLARY ELECTROPHORESIS WITH PRESSURE-DRIVEN MOBILIZATION

被引:43
作者
HUANG, TL
SHIEH, PCH
COOKE, N
机构
[1] Beckman Instruments, Inc., Fullerton, 92634, CA
关键词
CAPILLARY ISOELECTRIC FOCUSING; PRESSURE MOBILIZATION; PROTEIN SEPARATION; HEMOGLOBIN VARIANTS; MONOCLONAL ANTIBODY;
D O I
10.1007/BF02268277
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An isoelectric focusing (IEF) method in the capillary format with wide linear pH range (pH 3-10) and high resolution has been developed for separations of proteins. The methodology involves applying pressure and voltage simultaneously during the mobilization step of the IEF process, to elute the focused protein zones for detection. Capillary isoelectric focusing (CIEF) is performed in neutral, hydrophilic, coated capillaries of 50 mu m I.D., using various concentrations of methyl cellulose to reduce the distortion of focused zone by parabolic laminar flow. A linear relationship between the retention time and isoelectric point (pi) of protein standards was observed. The high resolution of this technique was demonstrated by the separation of hemoglobin variants F and A with pi difference of 0.05 pH units, and by the resolution of the isoforms of an anti-carcinoembryonic antigen monoclonal antibody.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 19 条
[1]   PERFORMANCE OF UNCOATED AND COATED CAPILLARIES IN FREE ZONE ELECTROPHORESIS AND ISOELECTRIC-FOCUSING OF PROTEINS [J].
BOLGER, CA ;
ZHU, M ;
RODRIGUEZ, R ;
WEHR, T .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (05) :895-906
[2]   ISOELECTRIC-FOCUSING BY FREE SOLUTION CAPILLARY ELECTROPHORESIS [J].
CHEN, SM ;
WIKTOROWICZ, JE .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) :84-90
[3]  
HJERTEN S, 1958, ARK KEMI, V13, P151
[4]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[5]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61
[6]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[7]   THEORETICAL AND EXPERIMENTAL-STUDY OF HIGH-PERFORMANCE ELECTROPHORETIC MOBILIZATION OF ISOELECTRICALLY FOCUSED PROTEIN ZONES [J].
HJERTEN, S ;
LIAO, JL ;
YAO, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :127-138
[8]   FAST AND HIGH-RESOLUTION ANALYSIS OF HUMAN-SERUM TRANSFERRIN BY HIGH-PERFORMANCE ISOELECTRIC-FOCUSING IN CAPILLARIES [J].
KILAR, F ;
HJERTEN, S .
ELECTROPHORESIS, 1989, 10 (01) :23-29
[9]   SEPARATION OF THE HUMAN TRANSFERRIN ISOFORMS BY CARRIER-FREE HIGH-PERFORMANCE ZONE ELECTROPHORESIS AND ISOELECTRIC-FOCUSING [J].
KILAR, F ;
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :351-357
[10]   CAPILLARY ISOELECTRIC-FOCUSING OF PROTEINS IN UNCOATED FUSED-SILICA CAPILLARIES USING POLYMERIC ADDITIVES [J].
MAZZEO, JR ;
KRULL, IS .
ANALYTICAL CHEMISTRY, 1991, 63 (24) :2852-2857